RADIANT: A fully configurable radiotherapy dose prediction framework

Read full text
Authors: Josiane Laure Pafeng, Adrian Celaya, Skylar Gay, David Fuentes, Mary K. Martel, Laurence E Court, Tucker Netherton
Cited by: 1
References: 33

Abstract

Abstract Objective. Treatment planning is a multi-disciplinary effort that requires medical decision-making, specialized training, and access to specialized software. Recently, deep learning has arisen as a powerful method for predicting patient-specific dose distributions. This work presents the radiotherapy dose inference and analysis toolkit (RADIANT), an open-source, fully configurable framework for 3D radiotherapy dose prediction. Built upon the Medical Imaging Segmentation Toolkit, RADIANT supports diverse network architectures, loss functions, and training strategies. Approach. We demonstrate its capabilities on cervical and prostate treatment plans generated with the radiation planning assistant, and on head and neck cancer plans from the American Association of Physicists in Medicine OpenKBP challenge data. For cervical cancer, we trained and compared nnU-Net, FMG-Net, W-Net, ddU-Net, and Swin UNETR using clinical metrics such as dose score, homogeneity index, and percent errors in D 95 , D 98 , and D 99 . Benchmarking was also performed on the OpenKBP dataset using dose score and dose-volume histogram (DVH) score for comparison with top challenge submissions. Results. Our results indicate that RADIANT provides a scalable platform for the rapid development and benchmarking of dose prediction models for selected cancer sites (cervix, prostate, head and neck). For cervical cancer, the best configuration (nnU-Net architecture, mean absolute error loss, cosine learning rate scheduler) achieved a dose score of 1.31 and sub- 1 % errors in D 95 and D 98 on the training set, and a dose score of 1.20 on the test set. The same configuration performed best on prostate data with a dose score of 1.96 on a test set. On the head and neck OpenKBP data, RADIANT achieved a dose score of 2.702 and a DVH score of 1.495, competitive with top challenge results. Significance. This work provides an open-source, fully configurable framework for deep learning–based dose prediction. RADIANT facilitates reproducible experimentation across data preprocessing, model configuration, training, and evaluation for multiple cancer sites and anatomical structures.

Fields of Study & Subjects

Advanced Radiotherapy Techniques Prostate Cancer Diagnosis and Treatment Radiation Therapy and Dosimetry

Publication details

Journal / source
Biomedical Physics & Engineering Express
Publisher
IOP Publishing
Volume
12
Issue
3
Pages
035046–035046
Publication date
20 May 2026
Language
EN