RATIONALE: Physiological studies showed benefits for bedside setting of personalized positive end-expiratory pressure (PEEP) by electrical impedance tomography (EIT), balancing lung overdistension and collapse. OBJECTIVES: To evaluate whether EIT-guided PEEP improves the clinical outcomes of patients with acute respiratory distress syndrome (ARDS) compared to the lower PEEP/FiO2 table strategy. METHODS: This randomized trial enrolled adult patients with moderate to severe ARDS across five sites in China from February 2022 to June 2023. Participants were randomly assigned to EIT-guided PEEP (collapse-overdistension crossing point value by decremental PEEP trial) or the classical lower PEEP/FiO2 table. The primary outcome was 28-day mortality. MEASUREMENTS AND MAIN RESULTS: The trial was terminated early for futility, based on a pre-planned interim analysis. A total of 190 patients were included and completed follow-up. PEEP levels didn't differ between groups during the first 7 days (difference in marginal means 0.2 [SE 0.1]; P = .187). At 28 days, mortality was 52 patients (55.9%) in the EIT-guided PEEP group and 51 patients (52.6%) in the lower PEEP/FiO2 table group (hazard ratio [HR] 0.96 [95% CI, 0.65-1.41]; P = .821). Ventilator-free days and other secondary clinical and safety outcomes did not differ, either. However, EIT-guided PEEP assigned higher PEEP and decreased mortality in patients with higher lung recruitability, as assessed by the recruitment-inflation ratio method (16 [35.6%] of 45 patients vs 27 [60.0%] of 45 patients; HR 0.49 [95% CI, 0.26-0.91]; P = .024). CONCLUSIONS: In patients with moderate to severe ARDS, EIT-guided PEEP did not significantly reduce 28-day mortality compared with the lower PEEP/FiO2 table strategy. Due to early termination, the study may have been underpowered to detect a clinically important difference. TRIAL REGISTRATION: clinicaltrials.gov NCT05207202.

Fields of Study & Subjects

Respiratory Support and Mechanisms Sepsis Diagnosis and Treatment Neonatal Respiratory Health Research

Publication details

Journal / source
American Journal of Respiratory and Critical Care Medicine
Publisher
Oxford University Press (OUP)
Volume
212
Issue
3
Pages
440–451
Publication date
5 January 2026
Language
EN