Calcium identification and scoring based on 3D transesophageal echocardiography - an exploratory study on aortic valve stenosis
Abstract
Abstract Introduction Calcium (Ca) score of the aortic valve has emerged as a tool for assessing aortic valve stenosis severity. The use of computed tomography (CT) is limited due to ionizing radiation and availability. Ca identification based on echo pixels using artificial intelligence (AI) systems has shown promising results in transthoracic echocardiography (TTE). Nevertheless, this technique is highly dependent on the patient’s acoustic window. We propose that transesophageal echocardiography (TEE) obviates the poor acoustic window and could be used for sequential follow-up of patients since no ionizing radiation is used. We also propose that 3D TEE could be more adequate to total valve calcium burden because it allows for identification of calcium pixels in a greater portion of the aortic valve, when compared to 2D techniques. Objective We aimed to perform an exploratory study to assess the feasibility of quantification of the calcium burden of the aortic valve imaged by 3D TEE and AI. Materials and methods Prospective analysis. Population: 24 individuals, 14 males, 23 patients with moderate or severe aortic stenosis by TTE, median age 76 years (IQR 12), 1 subject with normal aortic valve for validation of the model. Standard method for Ca scoring: CT scan. Imagiologic studies: TEE exam: 3D volume sets acquired in 3D zoom at the level of the aortic valve, stored in DICOM for post-processing. In the MPR quantification software contiguous 1.5 mm slices were obtained of the aortic valve in diastole, in short axis view. A Computer Vision model was applied to echocardiographic images, via adaptive image segmentation and Deep Learning to identify speckles and artifacts generated by the presence of Ca. The concordance of the Ca speckles of the 3D TEE images and the Agatston score was compared. An AI_Ca_score was obtained by the sum of the pixels of the Ca speckles of the 11 frames of each patients valve. Results The delay between TEE and CT scans was 65+-47 days. We found a significant positive correlation of the AI_Ca_score with the CT Agatston Ca_score: R= 0,65 (p
Fields of Study & Subjects
Cardiac Valve Diseases and Treatments
Cardiac Imaging and Diagnostics
Artificial Intelligence in Healthcare and Education
Publication details
- Journal / source
- European Heart Journal - Cardiovascular Imaging
- Volume
- 27
- Issue
- Supplement_1
- Publication date
- 1 January 2026
- Language
- EN