A deep learning model for continuous grading of aortic stenosis from b-mode transthoracic echocardiography

View at publisher
Authors: N Poilvert, S Goldstein, David S. Rubenson, D M Phelan, N P Kelly, M D Scherer, T V Johnson, A Marra, Y Thomas, J D Thomas
Cited by: 1

Abstract

Abstract Background Aortic stenosis (AS) is frequently under-diagnosed, particularly in the elderly and underserved populations [1]. While Doppler echocardiography is the gold standard for diagnosis, its scalability is limited by the need for expert interpretation. In this work, we introduce AutoAS, a deep learning model trained on 30,000 TTE studies to score AS severity on a continuous scale using only B-mode cine loops. Purpose To evaluate AutoAS as a stand-alone diagnostic tool and compare its aortic stenosis severity scoring capabilities to reference scores from a panel of 3 independent level III echocardiographers. Methods A validation dataset of 334 held-out patient studies (one study per patient) was assembled from both developmental and novel clinical sites. Each Doppler study was independently read by a panel of 3 level III echocardiographers that graded the severity of aortic stenosis on a 4-level scale (none, mild, moderate and severe). From panel severities, both a binary label and a continuous score were derived. The binary label referred to the presence or absence of "moderate to severe" aortic stenosis, while the score was curtailed to the interval [0, 1] and corresponded to the average of 3 individual scores (0 for none, 1/3 for mild, 2/3 for moderate and 1 for severe). Results In detecting "moderate to severe" aortic stenosis, AutoAS achieved an area under the ROC curve of 0.93 (95% CI 0.901–0.955), with a specificity of 92.6% and a PPV of 94.6%. When comparing scores from the model to reference panel scores, Pearson and Spearman correlation coefficients were 0.852 and 0.855 respectively (Figure 1). Moreover, looking at median model scores associated with each set of concordant panel scores, the slope of the regression line was 1.01 with an R^2 of 0.95 (Figure 2). Conclusion An automated deep learning model using only B-mode cine loops from TTE was able to grade the severity of aortic stenosis on a continuous scale with high correlation to a reference severity score derived from adjudicated severities of a panel of 3 level III echocardiographers.Figure 1 Figure 2

Fields of Study & Subjects

Cardiac Valve Diseases and Treatments Cardiovascular Function and Risk Factors Congenital Heart Disease Studies

Publication details

Journal / source
European Heart Journal - Cardiovascular Imaging
Publisher
Oxford University Press (OUP)
Volume
27
Issue
Supplement_1
Publication date
1 January 2026
Language
EN