Artificial intelligence for the assessment of aortic valve calcification in echocardiography

View at publisher
Authors: Pere López-Gutiérrez, Laura Galián-Gay, Alberto Morales-Galán, Neil Craig, J Garrido-Oliver, Josep Maria Alegret, Javier Bermejo, Francisco Calvo, Elena Ferrer‐Sistach, I Mendez, J Robredo Carmona, D Saura
+3 more Teresa Sevilla, M D Marc R Dweck, Andrea Guala
Cited by: 0

Abstract

Abstract Background Aortic valve calcification (AVC) is a fundamental mechanism and key predictor of aortic stenosis (AS) evolution. The gold standard for AVC quantification is computed tomography (CT) aortic valve Agatston calcium score (AVCS). Purpose To quantify AVC in echocardiography (TTE) using deep learning models. Methods 439 TTE and their corresponding CT AVCS from 234 patients included in the BICATOR [1] and a local study were partitioned at patient level into 165 TTEs (996 parasternal long and short axis and 3-chamber videos, from 7 centres) for training and cross-validation, and 274 (1488 videos, 9 centres) for testing, maintaining 89 studies (434 videos) from two centres exclusive for testing. Additionally, an external dataset, SALTIRE2 [2] comprising 255 TTEs (2159 videos) from 154 patients with mild or moderate AS was used to test model performance on independent data. Models were fine-tuned from PanEcho [3], with task-specific heads for binary classification and AVCS quantification. Five-fold cross-validation on training produced five models per task. After outlier removal, their averaged predictions were compared to reference CT AVCS. Results In the training cohort, median age was 53 [44; 72] years, with 32 (29%) females while 65 (59%) patients had a bicuspid aortic valve (BAV). AVC was absent in 37 (33%) patients, and those with calcification had a median AVCS of 1371 [687; 3112] AU. The median TTE to CT was 40 [7; 134] days. The testing cohort had a median age of 67 [48; 74] years and included 61 (22%) females and 126 (46%) patients with a BAV. AVC was present in 215 (79%) patients with a median AVCS of 1103 [530; 2067] AU. The cohort TTE-CT interval was 0 [0; 32] days. The model achieved excellent accuracy in distinguishing patients with and without AVC in the internal cross-validation (AUROC of 0.980 [0.961-0.993], figure 1), testing set (0.974 [0.962-0.983]) and in the external multicentre validation (0.983 [0.972-0.992]). AVCS quantification model performed well in cross-validation (R=0.89; error: 116 [0-551] AU) and remained robust in the testing set (R=0.64; error: 308 [3-977] AU) and external multicentre validation (R=0.47; error: 669 [184-1191] AU). Baseline AVCS predictions were significantly correlated with future progression of AS severity, as measured by changes in AV maximum velocity, pressure gradient, and CT AVCS (all p

Fields of Study & Subjects

Cardiac Valve Diseases and Treatments Artificial Intelligence in Healthcare and Education Cardiac Imaging and Diagnostics

Publication details

Journal / source
European Heart Journal - Cardiovascular Imaging
Volume
27
Issue
Supplement_1
Publication date
1 January 2026
Language
EN