Quantification of epicardial adipose tissue volumes - reproducibility and intermodality agreement of CCT and CMR

View at publisher
Authors: Judith Gronwald, Zoé M. Böttiger, Clara Hagedorn, Svante S. Gersch, Torben Lange, Sören Jan Backhaus, Ruben Evertz, Johannes Tammo Kowallick, Karl Toischer, Andreas Schuster, Alexander Schulz
Cited by: 0

Abstract

Abstract Background Increased epicardial adipose tissue volumes (EATV) exert adverse effects in cardiovascular disease. Emerging pharmacological strategies targeting elevated EATV may potentially mitigate these effects. Accurate quantification is therefore essential for reliable diagnosis and therapy monitoring. Cardiac computed tomography (CCT) is considered the reference standard for EATV quantification due to its high spatial and isotopic resolution. Cardiovascular magnetic resonance imaging (CMR) presents a radiation-free alternative. However, existing data on EATV derived from CCT and CMR lacks comparability as intermodality agreement and reproducibility have not been systematically investigated. Purpose This study aims to evaluate the reproducibility and intermodality agreement of EATV quantification using CMR compared to the reference standard CCT. Methods A total of 141 patients with severe aortic stenosis underwent paired CCT and CMR as part of a prospective clinical study. EATV quantification on CCT was performed by manual definition of the visceral pericardium and quantification of voxels within a threshold of -190 to -30HU. CMR-based quantification was carried out by manual volumetry and delineation of the visceral pericardium and epicardium on end-diastolic short-axis cine stacks. Details on acquisition parameters are compared in Table 1. Intermodality agreement was assessed using Spearman correlation and Bland-Altman analysis. Reproducibility was assessed in 20 patients per modality using the intraclass correlation coefficient (ICC) and coefficient of variation (CoV). Results A total of 137 patients with high-quality and complete imaging datasets were included for final analysis (78±6 years, 37,2% female). Median EATV measured by CMR was higher compared to CCT (89.8ml (73.0-113.5) vs. 73.2ml (56.8-101.7), p

Fields of Study & Subjects

Cardiovascular Disease and Adiposity Cardiac Imaging and Diagnostics Pericarditis and Cardiac Tamponade

Publication details

Journal / source
European Heart Journal - Cardiovascular Imaging
Volume
27
Issue
Supplement_1
Publication date
1 January 2026
Language
EN