Intraoperative transoesophageal echocardiographic detection of guidewire malposition and incomplete valve expansion in valve-in-valve transcatheter aortic valve implantation for Trifecta bioprosthesis failure: a case report

Read full text
Authors: Kenichi Watanabe, Nagataka Yoshihara, Hirokuni Akahori, Taichi Sakaguchi
Cited by: 0
References: 2

Abstract

Background: Valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) is widely used for failed surgical bioprostheses; however, procedural pitfalls remain, particularly in valves prone to early structural deterioration. Case summary: An 84-year-old woman with a failed 21 mm Trifecta bioprosthesis underwent ViV-TAVI. Although the guidewire crossed smoothly and fluoroscopy appeared reassuring, incomplete valve expansion occurred. Intraoperative transoesophageal echocardiography revealed that the guidewire had passed between degenerated leaflets rather than through the true central orifice. After repositioning under transoesophageal echocardiography guidance, full symmetric valve expansion and optimal haemodynamics were achieved. Discussion: This case highlights the risk of false procedural reassurance during ViV-TAVI and underscores the importance of actively confirming central guidewire trajectory, particularly in failed Trifecta bioprostheses.

Fields of Study & Subjects

Cardiac Valve Diseases and Treatments Aortic Disease and Treatment Approaches Infective Endocarditis Diagnosis and Management