Validation of the ESC 0/3h-algorithm with a novel high-sensitivity cardiac troponin I assay in patients with suspected myocardial infarction

Read full text
Authors: Koray Durak, Pedro López‐Ayala, Luca Koechlin, Jasper Boeddinghaus, Ivo Strebel, Sebastian Messingschlager, Arnaud Tanguy Champetier, Emel Kaplan, Lourdes Herraiz Recuenco, Oscar Miro, Michael Christ, Dagmar Iris Keller
+14 more Francisco Javier Martín‐Sánchez, Beata Morawiec, Jiří Pařenica, Gabrielle Huré, Tom Jamie Freihofer, Karin S. Wildi, Paolo Bima, Luca Crisanti, Thorald Stolte, Eliška Potluková, Danielle Menosi Gualandro, Felix Mahfoud, Christian Eugen Mueller, APACE investigators
Cited by: 0
References: 31

Abstract

Abstract Background There is uncertainty among physicians regarding the optimal clinical application of the novel high-sensitivity cardiac troponin I (hs-cTnI)-VITROS assay within the widely implemented upper reference limit (URL)-based ESC 0/3h-algorithm. Methods This prospective, international, multicenter study aimed to validate and compare different modifications of the URL-based ESC 0/3h-algorithm among adult patients presenting with suspected acute myocardial infarction (AMI) to the emergency department. Final diagnoses of AMI were centrally adjudicated by two independent cardiologists, blinded to hs-cTnI-VITROS concentrations. Discrimination was compared to the best validated hs-cTnT/I-assays. Clinical follow-up for cardiovascular death and AMI was conducted until five years. Results Among 1225 eligible patients (median age 63 years (IQR 52-75), 31.9% women), 18.9% were adjudicated as NSTEMI. Diagnostic discrimination of hs-cTnI-VITROS at 0h was very high (AUC 0.949, 95% CI 0.941–0.958), and comparable to hs-cTnI-Architect and hs-cTnT-Elecsys. Using the ESC 0/3h algorithm, 30.9% of patients were classified as rule-out (sensitivity 99.1%, NPV 99.5%) and 19.0% as rule-in (specificity 96.0%, PPV 82.8%). Substituting the HEART score for the GRACE score increased rule-out efficacy to 43.9%, while maintaining very high safety (sensitivity 99.6%; NPV 99.8%). Findings were consistent across predefined subgroups, in sensitivity analyses restricted to type 1 NSTEMI, using the 2h study blood sample (n=2249), and for the composite of cardiovascular death or AMI during five-year follow-up. Conclusions The ESC 0/3h-algorithm demonstrated excellent performance for rule-out of NSTEMI with greater efficacy when combined with the HEART-instead of the GRACE score. Registration https://clinicaltrials.gov/study/NCT00470587 Clinical Perspective What Is New? In a prospective, international multicenter cohort, the URL-based ESC 0/3h algorithm using the FDA-cleared hs-cTnI-VITROS assay achieved very high rule-out safety (sensitivity 99.1%, NPV 99.5%) but limited efficacy (30.9% rule-out) when combined with GRACE score

Fields of Study & Subjects

Acute Myocardial Infarction Research Cardiac Imaging and Diagnostics Coronary Interventions and Diagnostics

Publication details

Journal / source
European Heart Journal
Volume
47
Issue
Supplement_1
Publication date
1 October 2026
Language
EN