Stepwise intracoronary imaging assessment of lumen and vessel changes during drug-coated balloon angioplasty for in-stent restenosis

Read full text Summarise with VIRAT
Authors: Georgios M. Alexandridis, Jari A. van der Eijk, Karol Sadowski, Isabella Kardys, Wijnand K. den Dekker, Roberto Diletti, Rutger-Jan M. Nuis, K Mahmoud, Jeroen Wilschut, Nicolas M. Van Mieghem, Joost Daemen
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Background Drug-coated balloon (DCB) angioplasty is an established treatment for in-stent restenosis (ISR), and its procedural success mainly depends on optimal lesion preparation. However, angiography alone offers limited assessment of acute procedural effects, and the sequential vessel and lumen changes have not been comprehensively characterized with intracoronary imaging (ICI). Purpose Amid the continuing debate on the optimal DCB strategy, we aimed to characterize stepwise vessel and lumen changes during DCB angioplasty for ISR across three procedural stages: pre-lesion preparation, post-lesion preparation and post-DCB inflation, using intravascular ultrasound (IVUS) or optical coherence tomography (OCT). Methods This single-center, retrospective study included 20 patients (21 ISR lesions) undergoing ICI-guided DCB angioplasty with available imaging pullbacks at three stages: pre-lesion preparation (T1), post-lesion preparation (T2), and post-DCB inflation (T3). The vessel segment treated with DCB was identified on angiography and co–registered across all three pullbacks using reproducible landmarks, including the initial position of the ICI detector, previously implanted stents, and nearby side branches. This defined the region of interest (ROI), within which all study measurements were performed. Quantitative coronary angiography (QCA), IVUS, and OCT analyses were performed offline by a single trained observer. Changes in lumen and vessel parameters between stages were assessed using the Wilcoxon signed-rank test, where sample size permitted. Results Median [25th – 75th percentile] age was 69 [63 – 72] years, and 15 (75%) were male. Lesion preparation was mainly performed with non-compliant balloons (76%). QCA showed an incremental increase in minimal lumen diameter after lesion preparation (median difference (95% confidence interval) +0.6 (0.2 – 1.0) mm, p

Fields of Study & Subjects

Coronary Interventions and Diagnostics Cardiac Imaging and Diagnostics Peripheral Artery Disease Management

Publication details

Journal / source
European Heart Journal Supplements
Volume
28
Issue
Supplement_3
Pages
suag056.095
Publication date
1 March 2026
Language
EN