GC-FID quantification of methanol, ethanol, 2-propanol, acetone, ethylene glycol, diethylene glycol, 1,2-propylene glycol and 1,3-propylene glycol in plasma

Read full text
Authors: Mohsin El Amrani, Arjan Zandbergen, Mike Groot, Tim Bognàr, Erin H. Smeijsters, Kim C. M. van der Elst
Cited by: 1
References: 14

Abstract

Alcohol and glycol ingestion, including substances such as methanol, ethylene glycol, and isopropanol, constitute a serious medical emergency that requires prompt diagnosis and treatment of patients. Rapid and accurate quantification of these compounds in plasma is essential to guide clinical decision-making and prevent delays in treatment that could result in irreversible organ damage or death. Many healthcare facilities lack analytical methods capable of simultaneously quantifying both alcohols and glycols in a single run. This study describes the development and validation of a rapid gas chromatography-flame ionization detection (GC-FID) method for the simultaneous screening and quantification of methanol, ethanol, 2-propanol, acetone, ethylene glycol, diethylene glycol, 1,2-propylene glycol, and 1,3-propylene glycol in human plasma. Plasma samples were prepared using a protein precipitation technique with acetonitrile containing two internal standards: 2-butanol and 1,4-butanediol. Acetonitrile effectively precipitated plasma proteins. The supernatant was then subjected to GC-FID analysis for quantification of the target al.ohols and glycols. The total analytical run time was 5 minutes, enabling the quantification of eight analytes in a single injection. The method demonstrated excellent linearity, with correlation coefficients (R2) exceeding 0.9995 for all compounds. The linear dynamic range was 40-1280 mg/L for methanol, 2-propanol, acetone, ethylene glycol, diethylene glycol, 1,2-propylene glycol, and 1,3-propylene glycol, and 80-2560 mg/L for ethanol. Within-run and between-run precision and accuracy (CV and bias) for all analytes were within the predefined acceptance criteria of ±15%. No significant interference, carry-over, or matrix effects were observed, confirming the method's selectivity and robustness. The developed GC-FID method enables rapid, accurate, and simultaneous quantification of toxic alcohols and glycols in plasma within a 5-minute run time. The excellent linearity, precision, and selectivity of the method met al. analytical performance criteria, making it well-suited for routine clinical use. This method provides a valuable tool for timely diagnosis and management of suspected toxic alcohol and glycol ingestions in patients in emergency settings.

Fields of Study & Subjects

Poisoning and overdose treatments Alcohol Consumption and Health Effects Alcoholism and Thiamine Deficiency

Publication details

Journal / source
Journal of Analytical Toxicology
Publisher
Oxford University Press (OUP)
Volume
50
Issue
4
Publication date
9 February 2026
Language
EN