P-52. Hazard before the hardware? Bloodstream infections prior to implantation of durable left ventricular assist devices (LVAD)

Read full text
Authors: Patrick Chung Kay Tam, Manuela Carugati, Arthur W. Baker, Sana Arif, Madeleine R. Heldman, Eileen K Maziarz, Cameron R. Wolfe, Ilan Steven Schwartz, Bin Ni, Brennan J. Collis, Michael Edwards Yarrington, Sonya M. Kothadia
Cited by: 0

Abstract

Abstract Background Implantable mechanical circulatory support (MCS), such as left ventricular assist devices (LVADs), can improve survival in patients with end-stage heart failure. While post-implant complications including MCS-specific infections are well recognized, the outcomes of LVAD recipients with bloodstream infection (BSI) prior to device implantation have not been systemically studied. Methods We performed a single center retrospective study of all consecutive persons who received a Heartmate 3 (HM3) LVAD implanted at our institution between 1/1/17-12/31/23. We compared recipients with and without clinically significant BSI in the three months preceding device implantation. For these two groups, we also compared demographics, clinical characteristics, and outcomes, including post-implant BSI and one-year survival. Results Over the seven-year period, 498 patients received a HM3, of whom 31 (6%) had a pre-implant BSI (Table 1). The median time from pre-implant BSI to LVAD surgery was 13 days (interquartile range 6-18). The most common pathogens were Gram-positive organisms (22; 71%; Figure 1). Patients with pre-implant BSI were younger (p=.007), had lower Elixhauser co-morbidity indices (p=.004), and were in hospital longer immediately prior to LVAD surgery (p< .001) compared to patients without pre-implant BSI. Cumulative incidence of one-year post-implant BSI was similar in those with and without pre-implant BSI (16% v. 13%; p=.596). Of 31 patients with pre-implant BSI, 11 (35%) developed post-implant MCS-specific infection in the first year (n=9 percutaneous lead infections, n=1 device-specific BSI, n=1 infection of external surfaces of implant). Only one (3%) MCS-specific infection was attributed to the same pathogen (S. aureus) isolated in blood culture prior to implant. Patients with pre-implant BSI had longer index hospitalizations after LVAD implantation (47 v. 29 days; p< .001) but similar one-year survival compared to patients without pre-implant BSI (84% v. 81%; p=.707; Figure 2). Conclusion Pre-implant BSI in LVAD recipients was not associated with post-implant BSI. One-year survival was similar between LVAD recipients with and without pre-implant BSI. The risk factors, management, and outcomes of pre-implant BSI in LVAD recipients warrant further study. Disclosures Madeleine R. Heldman, MD, MS, Karius, Inc: Advisor/Consultant Cameron Wolfe, MBBS, Brio-VAD: Advisor/Consultant

Fields of Study & Subjects

Mechanical Circulatory Support Devices Infective Endocarditis Diagnosis and Management Nosocomial Infections in ICU

Publication details

Journal / source
Open Forum Infectious Diseases
Volume
13
Issue
Supplement_1
Publication date
1 January 2026
Language
EN