Effects of High-Flow Nasal Cannula and Helmet Continuous Positive Airway Pressure in Acute Hypoxemic Respiratory Failure

Read full text Summarise with VIRAT
Authors: Silvia Coppola, Mariarosa Pelliccia, Tommaso Pozzi, Giulia Catozzi, Cosmo Rocco, Alessandro Monte, Geraldina Besana, Davide Chiumello
Cited by: 0
References: 47

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

HEADINGS: The effects of high-flow nasal cannula (HFNC) and continuous positive airway pressure (CPAP) in patients with acute hypoxemic respiratory failure (AHRF) on respiratory mechanics and inspiratory efforts are not entirely understood. OBJECTIVES: To compare the physiologic effects of HFNC and helmet CPAP with respect to conventional oxygen therapy (COT) in terms of respiratory mechanics, inspiratory effort, gas exchange, and hemodynamics during AHRF. DESIGN: Crossover study. SETTING: General surgical-medical ICU of San Paolo University Hospital, Milan, Italy. PATIENTS: Thirty-three adult patients with AHRF, defined as an Pa o2 less than 60 mm Hg or an Pa o2 /F io2 less than 300 with a positive end-expiratory pressure (PEEP) level greater than or equal to 5 cm H 2 O, along with an Pa co2 less than 45 mm Hg. INTERVENTIONS: After support with COT, three types of respiratory support were applied in random order: HFNC with 60 L/min of flow and helmet CPAP with 5 or 10 cm H 2 O of PEEP. MEASUREMENTS AND MAIN RESULTS: Tidal volume, respiratory rate, inspiratory esophageal (ΔPes), and airway pressure swings were measured and an arterial blood gas analysis, along with hemodynamic data, was obtained after 20 minutes from the application of each respiratory support device. The application of HFNC and helmet CPAP at both 5 and 10 cm H 2 O of PEEP reduced minute ventilation (9.2 ± 3.2, 8.8 ± 2.3, and 9.3 ± 2.7 vs. 10.9 ± 3.3 L/min; p < 0.001) and ΔPes (-6.0 cm H 2 O [-7.8 to -4.0 cm H 2 O], -5.8 cm H 2 O [-7.2 to -4.5 cm H 2 O], and -5.9 cm H 2 O [-8.0 to -4.0 cm H 2 O] vs. -7.5 cm H 2 O [-10.8 to -6.5 cm H 2 O]; p < 0.001) while increasing Pa o2 /F io2 (188 ± 57, 208 ± 62, and 213 ± 69 vs. 129 ± 32; p < 0.001) with respect to COT; the application of 10 cm H 2 O of PEEP with helmet CPAP did not reduce inspiratory effort indices or increased oxygenation, but worsened mechanical power compared with HFNC and helmet CPAP with 5 cm H 2 O of PEEP. CONCLUSIONS: In patients with mild and moderate AHRF, HFNC and helmet CPAP ameliorated minute ventilation and respiratory rate, reduced inspiratory effort, and increased oxygenation compared with COT; the application of 10 cm H 2 O of PEEP during CPAP support worsened mechanical power.

Fields of Study & Subjects

Respiratory Support and Mechanisms Neonatal Respiratory Health Research Obstructive Sleep Apnea Research

Publication details

Journal / source
Critical Care Medicine
Volume
54
Issue
6
Pages
1420–1430
Publication date
1 April 2026
Language
EN