Four-Point Gore-Tex Scleral Fixation Using A Novel “ALL-IN-ONE” Hydrophilic Acrylic Intraocular Lens With Integrated Eyelets

Read full text
Authors: Bruno Fortaleza de Aquino Ferreira, João Vitor Bezerra Martins, Ronaldo Yuiti Sano, Caio V. Regatieri, Sérgio Luís Gianotti Pimentel
Cited by: 0
References: 11

Abstract

PURPOSE: To describe a surgical technique for four-point Gore-Tex scleral fixation of a foldable hydrophilic acrylic intraocular lens (IOL) with integrated eyelets (UnA IOL; Mediphacos, Belo Horizonte, Brazil) and report its postoperative outcomes. METHODS: A 62-year-old woman presented with persistent monocular diplopia after cataract surgery with in-the-bag implantation of a 3-piece IOL. Examination revealed IOL decentration secondary to zonular dialysis exceeding 120°, accompanied by iridodonesis. The unstable IOL was explanted, and pars plana vitrectomy was performed, followed by implantation of the UnA IOL using a 4-point Gore-Tex CV-8 scleral fixation technique. RESULTS: Monocular diplopia resolved entirely on the postoperative day, and best-corrected visual acuity improved from 20/30 preoperatively to 20/20 at 1 month, with the IOL well-centered and stable on ultrasound biomicroscopy. No suture erosion, persistent inflammation, ocular hypertension, or macular edema was observed, and the UnA IOL remained well-centered and stable during the 6-month follow-up. CONCLUSIONS: Four-point Gore-Tex scleral fixation using the UnA IOL demonstrated excellent centration, stability, and safety in the setting of significant zonular loss. Its purpose-built design, foldability, and accessibility make it a practical alternative for secondary IOL implantation in eyes lacking adequate capsular support.

Fields of Study & Subjects

Intraocular Surgery and Lenses Retinal and Macular Surgery Ophthalmology and Eye Disorders

Publication details

Journal / source
Retinal Cases & Brief Reports
Volume
20
Issue
4
Pages
602–606
Publication date
11 February 2026
Language
EN