A predictive model for optimal CT-guided thermal ablation margins in liver malignancies ≤3 cm: a retrospective cohort study

Read full text
Authors: Zhenkang Qiu, Guobao Wang, Zixiong Chen, Yuzhe Cao, Guisong Wang, Zhihui Zhong, Lijie Qiu, Tian Gao, Jingshuo Li, Han Qi, Fei Gao
Cited by: 1
References: 29

Abstract

BACKGROUND AND AIMS: Standardized quantitative criteria are lacking for the recommended circumferential thermal ablative margin in liver malignancies ≤3 cm. This study aimed to identify predictors of technical success in thermal ablation and develop a predictive model defining optimal ablation margins. METHODS: This retrospective study analyzed 979 patients undergoing computed tomography-guided radiofrequency or microwave ablation for liver malignancies ≤3 cm. Using a radiotherapy treatment planning system, preoperative tumor dimensions [maximum tumor area, preoperative maximum tumor area (PreMTA); tumor volume, preoperative tumor volume (PreTV)] and postoperative ablation characteristics [maximum ablation area, postoperative maximum ablation area (Post-MAA); ablation volume, postoperative ablation volume (PostAV)] were volumetrically quantified. Volume ratio (PostAV/PreTV) and area ratio (PostMAA/PreMTA) were calculated. Univariate and multivariate logistic regression identified predictors of residual tumor. A nomogram was developed and validated using Harrell's C-index, calibration curves, and receiver operating characteristic analysis. Size- and location-specific margin recommendations were derived mathematically. RESULTS: Residual tumor occurred in 91 patients (9.3%). Multivariate analysis identified adjacent large vessel [odd ratio (OR) = 1.97; P = 0.015], larger PreMTA (OR = 1.44; P = 0.014), and lower volume ratio (OR = 0.77; P = 0.009) as independent predictors. For non-perivascular tumors, optimal volume ratios were 4.3, 6.0, and 8.8 (corresponding ΔR = 0.3 cm, 0.8 cm, 1.6 cm) for diameters 1.0 cm, 2.0 cm, and 3.0 cm, respectively. A web-based calculator was implemented (https://fbzl.org/monitor/ablation_model.html). CONCLUSIONS: This study establishes and validates a computational model defining tumor size- and vessel proximity-specific optimal ablation margins for liver malignancies ≤3 cm. The web-accessible model provides evidence-based individualized ablation targets that optimize oncological efficacy while preserving parenchyma, replacing conventional fixed margins.

Fields of Study & Subjects

Hepatocellular Carcinoma Treatment and Prognosis Advanced Radiotherapy Techniques Management of metastatic bone disease

Publication details

Journal / source
International Journal of Surgery
Publisher
Ovid Technologies (Wolters Kluwer Health)
Volume
112
Issue
4
Pages
10078–10086
Publication date
13 January 2026
Language
EN