Assessing the readiness of Oxford Nanopore sequencing for clinical genomics applications

Read full text
Authors: Judith Arres, Santosh Elavalli, Shalini Behl, Daniel Matias Sanchez, Ayesha Al Ali, Abdelrahman Ahmed Yehia Abdelaziz Saad, Azza Attia, Cyla Minas, Sharika Pariyachery, Shariq Ahmed, Fatmah Aldhuhoori, Nitu Thulasidharan
+16 more Gurunath Katagi, Omar Soliman, Shilp Purohit, Vinay Kusuma, Raony G C C L Cardenas, Thyago Hermylly Santana Cardoso, Luis F. Paulin, Philippe Sanio, Joseph Mafofo, Haiguo Wu, Val V. Zvereff, Albarah El-Khani, Fahed Al Marzooqi, Tiago R. Magalhães, Fritz J. Sedlazeck, Javier Quilez
Cited by: 2
References: 55

Abstract

Long-read sequencing (LRS) technologies, namely, Oxford Nanopore Technologies (ONT) and Pacific Biosciences (PacBio), have emerged as promising solutions to overcome the limitations of short-read sequencing (SRS). Nevertheless, the still higher sequencing error rates compared with SRS, need for customized pipelines, rapidly updating software, and incipient scalability continue to present challenges for adopting ONT in standard clinical practice. Here we assess the performance of ONT (R9 and R10 chemistries) in comparison to Illumina and MGI across 17 well-characterized reference samples with 11 clinical variants representing nine different genetic diseases. To enable this, we have implemented a production-ready pipeline including SNV, indel, STR, SV, and CNV detection, alongside reporting key summary metrics to ensure high-quality data at the production sequencing level. Our results show high accuracy of ONT across SNVs ( F -score 0.978–0.983) and SVs ( F -score = 0.75) but still weaknesses across indels ( F -score 0.659–0.758). However, we highlight that ONT accurately detected all four pathogenic indels as well as the performance improvement in exons and with the newer R10 chemistry. We further demonstrated the importance of long reads to detect clinically impactful variants such as a FMR1 pathogenic expansion, often misclassified by SRS as being in the premutation range. Our multiplatform analysis and Sanger validation uncovered a 1 bp error in the Coriell annotation for a cystic fibrosis–causing indel in GM07829. This work underscores the growing readiness of ONT for clinical applications, highlighting both its advancements and its potential for broader adoption in clinical genomics and large-scale operations.

Fields of Study & Subjects

Genomics and Rare Diseases Genomics and Phylogenetic Studies Cystic Fibrosis Research Advances

Publication details

Journal / source
Genome Research
Publisher
Cold Spring Harbor Laboratory
Volume
36
Issue
3
Pages
460–471
Publication date
11 February 2026
Language
EN
Document type
Preprint