Knock out slow extraction using betatron sidebands at high harmonics
Abstract
Radio frequency knock out resonant slow extraction is a standard method for extracting stored particle beams from synchrotrons by transverse excitation. Excitation signals comprising many betatron sidebands have been shown to reduce intensity fluctuations of the extracted beam spill and are used at several facilities. In this contribution, the effect of individual sidebands at different harmonics on the spill quality is systematically studied using efficient noise excitation signals fully covering the respective sidebands. Particle tracking simulations show a clear correlation between the chosen excitation frequency and the spill quality. This relation is attributed to the spectrum of particle motion shortly before their extraction, and an empirical relation between the spectrum, the excitation frequency, and the resulting spill quality is given. Experiments show an additional reduction of pileup when using higher excitation frequencies. These insights have implications for an optimal design of excitation waveforms and hardware for knock out extraction systems.
Fields of Study & Subjects
Particle accelerators and beam dynamics
Particle Accelerators and Free-Electron Lasers
Radiation Therapy and Dosimetry
Publication details
- Journal / source
- Physical Review Accelerators and Beams
- Publisher
- American Physical Society (APS)
- Volume
- 29
- Issue
- 2
- Publication date
- 27 January 2026
- Language
- EN