Minimization of thermal deformation in crystal optics for high-repetition-rate FEL

Read full text
Authors: Lin Zhang, Jerome Hastings, Zhirong Huang, Jean-Pierre Torras, Diling Zhu
Cited by: 1
References: 39

Abstract

Minimizing thermal deformation in X-ray crystal optics is crucial for preserving coherence and wavefront in high-repetition-rate free-electron lasers (FELs). This study presents two approaches to reduce pulse-by-pulse transient thermal deformation in diamond crystals used in cavity-based X-ray FELs (CBXFELs): (i) cryogenic cooling with liquid nitrogen (LN 2 ), and (ii) second-order correction via focusing optics. We revisit the temperature-dependent thermal-mechanical properties of diamond and silicon, and implement a finite-element analysis method to accelerate convergence to a quasi-steady-state regime. Results show that LN 2 -cooled diamond crystals meet the stringent deformation requirement of less than 15 pm RMS for the pulse at the mJ scale at 1 MHz repetition frequency, and up to 1.5 mJ for 100 kHz. Second-order correction by using focusing elements within the cavity can reduce the impact of thermal deformation for both LN 2 and water cooling.

Fields of Study & Subjects

Particle Accelerators and Free-Electron Lasers Advanced X-ray Imaging Techniques High-pressure geophysics and materials

Publication details

Journal / source
Journal of Synchrotron Radiation
Publisher
International Union of Crystallography (IUCr)
Volume
33
Issue
2
Pages
260–270
Publication date
28 January 2026
Language
EN