Minimization of thermal deformation in crystal optics for high-repetition-rate FEL
Abstract
Minimizing thermal deformation in X-ray crystal optics is crucial for preserving coherence and wavefront in high-repetition-rate free-electron lasers (FELs). This study presents two approaches to reduce pulse-by-pulse transient thermal deformation in diamond crystals used in cavity-based X-ray FELs (CBXFELs): (i) cryogenic cooling with liquid nitrogen (LN 2 ), and (ii) second-order correction via focusing optics. We revisit the temperature-dependent thermal-mechanical properties of diamond and silicon, and implement a finite-element analysis method to accelerate convergence to a quasi-steady-state regime. Results show that LN 2 -cooled diamond crystals meet the stringent deformation requirement of less than 15 pm RMS for the pulse at the mJ scale at 1 MHz repetition frequency, and up to 1.5 mJ for 100 kHz. Second-order correction by using focusing elements within the cavity can reduce the impact of thermal deformation for both LN 2 and water cooling.
Fields of Study & Subjects
Particle Accelerators and Free-Electron Lasers
Advanced X-ray Imaging Techniques
High-pressure geophysics and materials
Publication details
- Journal / source
- Journal of Synchrotron Radiation
- Publisher
- International Union of Crystallography (IUCr)
- Volume
- 33
- Issue
- 2
- Pages
- 260–270
- Publication date
- 28 January 2026
- Language
- EN