On the optimization of the geometric pattern for structured illumination based X-ray phase contrast and dark-field imaging: a simulation study and its experimental validation
Abstract
Phase contrast and dark-field imaging are relatively new X-ray imaging modalities that provide additional information to conventional attenuation-based imaging. However, this new information comes at the price of a more complex acquisition scheme and optical components. Among the different techniques available, such as grating interferometry or edge illumination, modulation-based and more generally single-mask/grid imaging techniques simplify these new procedures to obtain phase and dark-field images by shifting the experimental complexity to the numerical post-processing side. This family of techniques involves inserting a membrane into the X-ray beam that locally modulates the intensity to create a pattern on the detector which serves as a reference. However, the topological nature of the mask used seems to determine the quality of the reconstructed phase and dark-field images. We present in this article an in-depth study of the impact of the membrane parameters used in a single-mask imaging approach. A spiral topology seems to be an optimum both in terms of resolution and contrast-to-noise ratio compared with random and regular patterns.
Fields of Study & Subjects
Advanced X-ray Imaging Techniques
Crystallography and Radiation Phenomena
Radiation Shielding Materials Analysis
Publication details
- Journal / source
- Journal of Synchrotron Radiation
- Publisher
- International Union of Crystallography (IUCr)
- Volume
- 33
- Issue
- 3
- Pages
- 806–817
- Publication date
- 8 April 2026
- Language
- EN