Retracted: High-Sensitivity Staged Zero-Sequence Overcurrent Protection for High-Resistance Grounding Faults in Low-Resistance Grounded Distribution Networks

Read full text Summarise with VIRAT
Authors: Fengxiang Wang, Ao Yin, Jufeng Li, Yinghong Zhao, Yubin Huang
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

To address the limitations of conventional zero-sequence overcurrent protection in low-resistance-to-ground systems—where high settings are required to avoid tripping due to maximum capacitive currents, resulting in unreliable detection of high-resistance ground faults—this paper proposes a highly sensitive segmented zero-sequence overcurrent protection method. Based on analyzing the zero-sequence current distribution characteristics during single-phase ground faults in low-resistance grounded systems, this method exploits the fundamental feature that the zero-sequence current in the faulty feeder consistently exceeds that in non-faulty feeders by a factor of ten or more. It decomposes the conventional single-stage zero-sequence overcurrent protection into three fixed-time-limit stages (Stages IIIA, IIIB, and IIIC). By lowering the trip current threshold of the lowest stage (Stage IIIC) to 3A and applying the “lateral coordination” principle, selective coordination is achieved through current differences between feeder protections. This approach simultaneously satisfies the sensitivity requirements for high-resistance faults and the selectivity demands for metallic faults. This paper details the current setting methods for each protection stage and the coordination principles for operating time limits, providing specific setting calculation examples. For instance, the fault current range of 0-600A is divided into three intervals: above 75A, 15-75A, and 3-15A, with corresponding operating times of 0.6s, 1.2s, and 1.8s. MATLAB simulations and field test data from an 110kV substation in Guangxi Province demonstrate that this method reliably detects high-resistance ground faults with transition resistances up to 1500Ω. It also ensures selectivity during metallic faults through lateral coordination between feeders. The proposed method requires no new device development or installation, achieving its objectives solely through rational reconfiguration of existing protection settings, thereby offering significant practical engineering value.

Fields of Study & Subjects

Power Systems Fault Detection Electrical Fault Detection and Protection Power System Optimization and Stability

Publication details

Journal / source
IEEE Access
Pages
1–1
Publication date
1 January 2026
Language
EN