An Analytical Framework for Modeling Inhomogeneities in Open-Ended Coaxial Probe Measurements

Read full text
Authors: Rotem Gal-Katzir, Emily Porter, Yarden Mazor
Cited by: 0
References: 18

Abstract

Open-ended coaxial probes (OECP) are commonly used for dielectric characterization, across the RF/Microwave frequency range. A significant challenge in using this measurement technique is to measure properties of inhomogeneous materials, due to the complexity of modeling the fields in the inhomogeneous sample. In this letter we present a theoretical model and an experimental verification for the extraction of the physical parameters of a small scatterer from open-ended coaxial probe reflection measurements. Using an analytical framework, we show that the depth and radius of a conductive scatterer can be extracted from reflection data obtained using two different probes. A 3D printed inhomogeneous sample was produced by embedding a conductive scatterer within a homogeneous dielectric sample. With average relative errors of 13%−20%, the results show that two scatterer parameters (radius and depth) can be accurately estimated relying solely on the approximate, dipolar, analytical model.

Fields of Study & Subjects

Surface and Thin Film Phenomena Advancements in Photolithography Techniques Electron and X-Ray Spectroscopy Techniques

Publication details

Journal / source
IEEE Antennas and Wireless Propagation Letters
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Volume
25
Issue
7
Pages
2664–2668
Publication date
27 April 2026