A >130-dB CMRR Capacitively Coupled Chopper Instrumentation Amplifier Employing Orthogonal Timing Mismatch Averaging for Biosignal Sensing

View at publisher
Authors: Jianan Zheng, Longbin Zhu, Wenjie Wang, Siyuan Xie, Zhijun Zhou, Keping Wang
Cited by: 0
References: 14

Abstract

This paper presents a capacitively-coupled chopping instrumentation amplifier (CCIA) with orthogonal timing mismatch averaging (OTMA) technique for bio-signal sensing. OTMA employs additional pairs of choppers in input and feedback networks, to mitigate all the passive component mismatches through four orthogonal phases. OTMA substantially increases the common-mode rejection ratio (CMRR) without the need for complex correction loops or extra pathways. Designed in 130 nm CMOS technology, the proposed CCIA with OTMA draws 3.5 μA from a 1.8-V supply and exhibits 0.63 μVrms input-referred noise over 0.5-200 Hz. It achieves >130 dB CMRR with a compact chip area.

Fields of Study & Subjects

Analog and Mixed-Signal Circuit Design Radio Frequency Integrated Circuit Design Low-power high-performance VLSI design

Publication details

Journal / source
IEEE Sensors Letters
Volume
10
Issue
2
Pages
1–4
Publication date
12 January 2026