Strengthening the Distribution System for Extreme Wind Events Through Situational Awareness-Based Resilience Assessment

View at publisher Summarise with VIRAT
Authors: Krishna Kant Dixit
Cited by: 0
References: 12

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The frequency and severity of extreme wind events, particularly cyclones, continue to rise, it is imperative that power distribution networks be equipped with a strategy that is both resilient and flexible in order to improve their resilience. This paper introduces a situational awareness-grounded methodology of resilience assessment, which encompasses a mesh grid methodology. The goal of this methodology is to reduce the multi-dimensional effects of cyclone trajectories on the distribution network to a two-dimensional picture. This transformation makes it possible to precisely identified weak points in the network, which is possible because of the network. A hybrid data-driven approach that combines Complex Networks (CN) with monitoring assisted by Unmanned Aerial Vehicles (UAVs) and micro-Phasor Measurement Units (PMUs) is utilized in order to identify vulnerable nodes and priorities them. The degree of correlation is estimate by taking into account the topographic characteristics of each node. This exercise brings to light the significant influence that latitude, elevation, and the potential water levels have on the distribution system's ability to withstand disruptions. At the same time that the minimum, intermediate, and maximum paths of cyclones are, take into consideration, the most effective mitigation techniques are discover to improve the resilience of networks. To justify these strategies, the resilience trapezium framework is applied. The usefulness of the proposed methodology is test on the IEEE 33 bus distribution system, which is subject to five geographically different locations that are prone to cyclones. The analysis is do using twenty years of historical data. The results show the effectiveness of the suggested strategy to the increased resistance to the development of the distribution networks to the event of strong wind.

Fields of Study & Subjects

Infrastructure Resilience and Vulnerability Analysis Optimal Power Flow Distribution Power System Optimization and Stability

Publication details

Journal / source
International Conference on Power Electronics & IoT Applications in Renewable Energy and its Control (PARC)
Pages
1–4
Publication date
20 February 2026
Language
EN