High-$T_{\mathrm{c}}$ DC SQUID and its Applications in NDE

View at publisher
Authors: KeBo Lü, Jiajun Chen, Gaoping Lei, Yifan WU, Zhidan Zhang, Hai Wang, Xiangyan Kong
Cited by: 0
References: 16

Abstract

Nondestructive defect diagnosis of OLED arrays is challenging because pixel pitch can be below 100 μm and the drive current per pixel is often at the μA level, while practical cryogenic magnetometry is spatially limited by sensor stand-off. This work scans the magnetic field generated by the row and column drive currents in the OLED leads; two orthogonal line scans along the x and y axes localize defects by identifying the intersection of anomalous rows and columns, with the magnitude of signal attenuation providing additional discrimination. A high-TcSQUID planar first-order gradiometer is implemented and shows good agreement with electromagnetic simulations. Compared with a room-temperature TMR sensor, the SQUID platform achieves a 45.8 dB effective sensitivity advantage under practical lift-off constraints. The method offers a fast and scalable route for OLED/PCB defect localization when high sensitivity is required but spatial resolution is limited.

Fields of Study & Subjects

Non-Destructive Testing Techniques Magnetic Field Sensors Techniques Superconducting Materials and Applications

Publication details

Journal / source
IEEE Transactions on Applied Superconductivity
Volume
36
Issue
5
Pages
1–5
Publication date
10 February 2026
Language