Selective Harmonic Mitigation Model Predictive Control for Grid-Connected Converters Working With a Very Low Apparent Switching Frequency
Abstract
This article proposes a Selective Harmonic Mitigation Model Predictive Control (SHM-MPC) strategy for grid-connected converters working with a very low apparent switching frequency. A three-level SHM pattern in accordance with grid-code standards, a variable sampling-period hardware implementation, and an improved problem formulation are realized, which respectively comply with the IEEE 519-2022 standard limits, adapt to grid-frequency variations, and minimize real-time processing requirements. The proposed solution is experimentally validated on a scaled-down grid-connected three-level Cascaded H-Bridge (3L-CHB) converter working at 350 Hz and compared against a standard problem formulation. The results indicate that the proposed solution is feasible, the algorithm can be solved in real time, and it can be implemented on a Digital Signal Processor (DSP), while emphasizing the impact of grid frequency variability. These results are further illustrated in a supplementary video containing all the experimental tests, demonstrating that operating with a very low apparent switching frequency, combined with a distorted and variable grid, imposes hardware design restrictions that must be considered in the problem formulation to enable implementation without degrading either the current harmonic spectrum or the THD.
Fields of Study & Subjects
HVDC Systems and Fault Protection
Multilevel Inverters and Converters
Microgrid Control and Optimization
Publication details
- Journal / source
- IEEE Transactions on Power Electronics
- Publisher
- Institute of Electrical and Electronics Engineers (IEEE)
- Volume
- 41
- Issue
- 8
- Pages
- 12553–12565
- Publication date
- 3 March 2026
- Language
- EN