Improved Fault-Tolerant Carrier-Based Modulation for Maximum DC-Link Voltage Utilization in FPSW-PMSM Drive System

View at publisher
Authors: Hongwei Wang, Hanying Gao, Quntao An, Jianyong Su
Cited by: 1
References: 12

Abstract

Compared to the traditional star topology, the five-phase series-end winding permanent magnet synchronous motor (FPSW-PMSM) presents a unique fault characteristic under an open-circuit fault of the central bridge leg. However, the conventional current-reconstruction-based fault-tolerant strategy, which projects the asymmetric fundamental components onto the x-y subspace, leads to a reduction in DC-link voltage utilization. This letter proposes an improved fault-tolerant carrier-based modulation strategy. The harmonic current references are firstly derived under fault-tolerant conditions. Then, the compensation is applied to the projection of the asymmetric fundamental components in the harmonic subspace. The correction to the conventional method is achieved by reconstructing the post-fault voltage vector distribution, which in turn maximizes the DC-link voltage utilization. Experimental results demonstrate that the proposed strategy improves the DC-link voltage utilization of the drive system by 4.21% and 5.9% under minimum copper loss and maximum torque conditions, respectively.

Fields of Study & Subjects

Multilevel Inverters and Converters Power Systems Fault Detection Electromagnetic Compatibility and Noise Suppression

Publication details

Journal / source
IEEE Transactions on Power Electronics
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Volume
41
Issue
9
Pages
14379–14384
Publication date
13 April 2026