Online Estimation of VSI Nonlinearity in PMSM Based on Third-Order Generalized Integrator
Abstract
Voltage-source-inverter (VSI) nonlinearity causes current distortion and degrades the accuracy of parameter identification and sensorless control in permanent magnet synchronous machine (PMSM) drives. This letter proposes a novel online estimation method for VSI nonlinearity voltage based on third-order generalized integrators (TOGIs). The impacts of limited current control bandwidth and phase misalignment on estimation accuracy are systematically investigated for the first time. To address these issues, the proposed method employs TOGIs to extract the sixth-order harmonic amplitudes from both thed-axis reference voltageud,refand the dead-time coefficientDd, and easily estimates the nonlinearity voltage through their ratio, thereby enabling more accurate estimation by effectively eliminating errors induced by limited current control bandwidth and phase misalignment. Experimental results validate the effectiveness and superiority of the proposed method.
Fields of Study & Subjects
Control Systems and Identification
Advanced Adaptive Filtering Techniques
Blind Source Separation Techniques
Publication details
- Journal / source
- IEEE Transactions on Power Electronics
- Publisher
- Institute of Electrical and Electronics Engineers (IEEE)
- Volume
- 41
- Issue
- 10
- Pages
- 16778–16784
- Publication date
- 28 May 2026
- Language