Bunch Compression Monitoring in Longitudinal Electron Bunch Diagnostics Using Zero-Bias Schottky Diode and AlGaAs/GaAs TeraFET Direct THz Detectors

Read full text Summarise with VIRAT
Authors: Rahul Yadav, Michael Kuntzsch, U. Lehnert, Sascha Preu, Andreas Penirschke
Cited by: 0
References: 33

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Electron bunch compression is a crucial technique for generating high-brilliance, high-peak-current electron beams in third-generation and upcoming fourth-generation accelerator-based light sources. Bunch compression monitors (BCM) are required for non-invasive, shot-to-shot monitoring of the electron bunch compression state, allowing for precise beam characterization to optimize machine configuration and provide valuable real-time feedback to beamline scientists or directly to the machine, e.g., via a feedback loop, ultimately enhancing the overall operation and performance of the free electron laser (FEL) facility. In this work, two promising room-temperature operable BCMs have been investigated: zero-bias Schottky diodes (ZBSD) and AlGaAs/GaAs transistor-based (TeraFET) direct THz detectors. The application-oriented characterization of developed technologies was carried out at the ELBE facility located at the Helmholtz-Zentrum Dresden-Rossendorf in Germany. The electron bunch charge sweep was performed from 18 pC to 220 pC. Based on the simulation, the shortest bunch length is estimated to be below 0.5 ps. We estimate the minimum detectable bunch charge of the ZBSD detector to be in the single-digit pC range for single-bunch measurements. Both ZBSD and TeraFET detectors detect bunch charges non-destructively. Bunch compression was compared with a commercially available power meter based on a thermal detection principle, showing that the ZBSD is considerably more sensitive but saturates earlier. At the same time, the TeraFET is excellently suited for a high bunch charge of a few 100 pC with little saturation. The novelty of the proposed technologies lies in: (1) combined ZBSD and TeraFET provides a solution for BCMs in a wide range of bunch charges, and (2) their capability to have intrinsic response time on ps-scale, contrary to the ms to μs-scale response time of the conventionally used thermal-based power meters. To the best of the author's knowledge, TeraFETs are tested for the first time in the BCM application. These detectors are expected to be commissioned at free-electron laser facilities in the near future.

Fields of Study & Subjects

Particle Accelerators and Free-Electron Lasers Particle accelerators and beam dynamics Particle Detector Development and Performance

Publication details

Journal / source
IEEE Transactions on Terahertz Science and Technology
Volume
16
Issue
6
Pages
662–671
Publication date
25 March 2026
Language
EN