Why Temporary Pacing in Acute Inferior Myocardial Infarction or No‐Reflow Becomes a Trigger—Not a Remedy—For Ventricular Fibrillation: Undersensing, “R‐On‐T”, Catheter Trauma and the Ischaemic Substrate

Read full text
Authors: Zhong‐Qun Zhan, Hai‐Jun Xu
Cited by: 0
References: 10

Abstract

Temporary pacing during acute inferior MI or no-reflow can trigger ventricular fibrillation rather than prevent it. Four mechanisms are highlighted: (1) acute ischemia lowers VF threshold and creates repolarization heterogeneity; (2) fragmented electrograms cause undersensing and asynchronous spikes; (3) bradycardia-related long RR cycles position spikes on the T-wave ("R-on-T"); and (4) catheter micro-displacement induces mechanical extrasystoles. We propose a bedside decision framework-three questions before pacing-and a prevention bundle focused on urgent ischemia reversal, continuous electrogram surveillance, and early electrode removal. Bradycardia in this setting is often transient, but the electrophysiological vulnerability is not. Treating ischemia first and avoiding unnecessary pacing are paramount to prevent iatrogenic arrhythmia.

Fields of Study & Subjects

Cardiac electrophysiology and arrhythmias Cardiac Arrhythmias and Treatments Cardiac pacing and defibrillation studies

Publication details

Journal / source
Annals of Noninvasive Electrocardiology
Volume
31
Issue
1
Pages
e70149–e70149
Publication date
1 January 2026