Same‐day fluorescence confocal microscopy of MRI ‐targeted prostate biopsies: A feasibility study

Read full text
Authors: Salim K. Younis, Mohamad Watfa, Lin Wang, Karim Daher, Nicolas Adrianto Soputro, Abdulrahman Al‐Bayati, Samarpit Rai, Rui M. Bernardino, Ruben Olivares, Riccardo Autorino, Christopher J. Weight, Jihad Kaouk
+2 more Jane K. Nguyen, Zeyad R. Schwen
Cited by: 1
References: 13

Abstract

OBJECTIVES: To determine the diagnostic performance of ex vivo fluorescence confocal microscopy (FCM) for prostate cancer detection in magnetic resonance imaging (MRI)-targeted biopsy specimens using final histopathology as the reference standard, and to quantify workflow component times relevant to same-day implementation. PATIENTS AND METHODS: In this single-centre prospective observational study, men undergoing MRI-targeted transperineal prostate biopsy were enrolled. Targeted biopsy cores were imaged ex vivo using a Histolog® FCM scanner (SamanTree Medical SA, Lausanne, Switzerland) after rapid acridine orange immersion and prior to routine histopathological processing. Two board-certified genitourinary pathologists independently reviewed FCM images in a blinded fashion and classified each specimen as positive or negative for prostate cancer and clinically significant cancer (CSC), defined as International Society of Urological Pathology Grade Group (GG) ≥2. Diagnostic performance was calculated against final histopathology. Workflow feasibility was assessed by measuring specimen preparation, scanning, and interpretation times. Interobserver agreement and exploratory discordance analyses were performed. RESULTS: A total of 50 MRI-targeted biopsy specimens from 44 patients were analysed, of which 33 (66%) contained prostate cancer and 17 (52%) met criteria for CSC. For cancer detection, Reader 1 achieved 87.9% sensitivity and 94.1% specificity, and Reader 2 achieved 97.0% sensitivity and 76.5% specificity, with overall accuracy of 90% for both readers. Interobserver agreement for cancer detection was 88% (κ = 0.74), and for CSC was 86% (κ = 0.61). Mean specimen preparation and interpretation times were ~2 min each, with standardised scanning time of 50 s, enabling complete FCM assessment in

Fields of Study & Subjects

Prostate Cancer Diagnosis and Treatment MRI in cancer diagnosis Advanced Fluorescence Microscopy Techniques

Publication details

Journal / source
British Journal of Urology
Publisher
Wiley
Volume
138
Issue
S1
Pages
S112–S120
Publication date
28 March 2026
Language
EN