Photon‐Counting CT for Diagnosing Vertical Root Fractures in Teeth With Metal Posts: An Ex Vivo Comparative Analysis With Four CBCT Devices

Read full text
Authors: Renata M. S. Leal, Fernanda Bulhões Fagundes, Maria F. S. A. Bortoletto, Samuel Cavalli Kluthcovsky, Walter Coudyzer, Bruno Cavalini Cavenago, Reinhilde Jacobs, Rocharles Cavalcante Fontenele
Cited by: 2
References: 36

Abstract

OBJECTIVE: Photon-counting computed tomography (PCCT) represents a major innovation in X-ray detection technology, offering improved signal efficiency and reduced electronic noise compared with cone-beam computed tomography (CBCT), which can enhance image quality. This study aimed to evaluate the diagnostic performance of PCCT in detecting vertical root fractures (VRF), in comparison with four CBCT devices. METHODOLOGY: Eighteen single-rooted teeth were endodontically treated, and VRF was induced in eight of them. Each tooth was individually placed into the mandibular first premolar empty socket of an anthropomorphic phantom and scanned under three conditions: without a metal post, with a nickel-chromium metal post (Ni-Cr), and with a cobalt-chromium metal post (Co-Cr) in five CT devices: the NAEOTOM Alpha PCCT (Siemens Healthineers) device and four CBCT devices (3D Accuitomo 170-Morita, Veraview X800-Morita, NewTom VGi evo-NewTom, and Carestream 9600-Carestream). The highest-resolution protocol available on each device was used, resulting in a total of 270 scans. Five experienced dentomaxillofacial radiologists independently and blindly evaluated the scans using a five-point confidence scale. Diagnostic accuracy was assessed by calculating the area under the ROC curve (AUC), sensitivity, and specificity, with results compared by two-way ANOVA with post hoc Tukey's test (α = 0.05). RESULTS: NewTom VGi and PCCT devices showed significantly higher AUC values than the Veraview X800, regardless of the metal post material (p < 0.05). CS9600 and PCCT devices exhibited significantly higher sensitivity values in diagnosing with Ni-Cr posts than the Accuitomo 3D and Veraview X800 devices (p < 0.05). With the Co-Cr metal post, the NewTom VGi, CS9600, and PCCT devices showed significantly higher sensitivity values compared to the Veraview X800 device (p < 0.05). There were no statistically significant differences in specificity, regardless of the CT device or metal post material (p > 0.05). CONCLUSIONS: The NEAOTOM Alpha PCCT showed high diagnostic accuracy for VRF detection in an ex vivo model, comparable to high-resolution CBCT devices, highlighting its diagnostic performance under controlled ex vivo conditions.

Fields of Study & Subjects

Dental Radiography and Imaging Advanced X-ray and CT Imaging Facial Trauma and Fracture Management

Publication details

Journal / source
International Endodontic Journal
Publisher
Wiley
Volume
59
Issue
4
Pages
718–727
Publication date
9 January 2026
Language