Accelerometric Assessment of Gastric Contractility Using the Atmo Wireless Motility Capsule

View at publisher
Authors: William Lee Hasler, Thomas Abell, Ashok Attaluri, William D. Chey, Michael Cline, Richard B. Gearry, Peter R. Gibson, Vincent Ho, Allen A. Lee, Anthony J Lembo, Amir Masoud, R McCallum
+10 more Baharak Moshiree, Eamonn M. M. Quigley, Satish R. Rao, Mayra J. Sanchez, IRENE SAROSIEK, Abigail M. Stocker, Brian C. Surjanhata, Phoebe A. Thwaites, Jerry Zhou, Braden Kuo
Cited by: 1
References: 13

Abstract

BACKGROUND: Patients with gastric dysmotility exhibit abnormal transit and reduced contractility, for which quantification is limited with current methodologies. The Atmo Capsule is a wireless motility capsule that measures regional gastrointestinal transit. We tested its technical capabilities to evaluate gastric contractility by detecting changes in capsule acceleration during transit. METHODS: Data from 91 healthy controls and 182 patients with suspected dysmotility who ingested the Atmo Capsule following a standardized protocol were included. Gastric emptying times (GET) ≥ 5 h were considered delayed. Contraction frequencies (cycles per minute [cpm]) and amplitudes (as arbitrary units [au]) were identified following Fast Fourier Transformation of accelerometer data using 5-min windows and were assessed in 30-min windows post-ingestion (early gastric phase) and before gastric emptying (late gastric phase). Data were compared via ANOVA, using Bonferroni corrections, between healthy controls, patients with normal gastric emptying, and patients with delayed gastric emptying. KEY RESULTS: Gastric emptying was delayed in 53/182 (29%) patients. Three cpm contraction frequencies were identified across both gastric phases in controls and patients. Contraction amplitudes did not differ between groups in the early gastric phase. In the late phase, mean amplitudes were lower in patients with delayed gastric emptying (6.4 au) compared with subjects with normal gastric emptying (controls, 9.7 au, p < 0.0001; patients, 8.6 au, p < 0.0001). CONCLUSIONS & INFERENCE: The Atmo Capsule enables precise quantification of gastric contraction profiles, permitting differentiation of normal from pathological motor patterns. Findings of this technical assessment support its potential for evaluating gastric physiology and detecting pathophysiological patterns of gastric dysmotility.

Fields of Study & Subjects

Gastrointestinal motility and disorders Gastrointestinal Bleeding Diagnosis and Treatment Gastroesophageal reflux and treatments

Publication details

Journal / source
Neurogastroenterology & Motility
Publisher
Wiley
Volume
38
Issue
2
Pages
e70255–e70255
Publication date
1 February 2026
Language
EN