In the Search of Noninvasive Methods Delineating Left Bundle Branch Block Amendable With Conduction System Pacing

Read full text Summarise with VIRAT
Authors: Tadej Žlahtič, Vito Starc, David Žižek, Martin Rauber, Bor Antolič, Miha Mrak, Maja Ivanovski, Anja Zupan Mežnar
Cited by: 0
References: 11

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Conduction system pacing (CSP) is an emerging new method of cardiac resynchronization therapy (CRT), however, one third of patients with left bundle branch block (LBBB) have distal conduction disease, which is not amenable to correction with CSP. There is an emerging need for tailored analysis of ventricular depolarization patterns for patient selection for CRT pacing modality. We retrospectively analyzed 12 lead hrECGs, equivalent dipole (ED) trajectories and standard transthoracic echocardiograms of 18 heart failure patients fulfilling Strauss criteria for LBBB and indication for CRT randomized to the CSP arm of the ongoing CSP-Sync study (NCT05155865). Based on achievement of left bundle branch capture with shortening of left ventricular activation time, 12 patients had proximal LBBB (pLBBB group), and 6 had intact proximal LBBB conduction (dLBBB group) with similar average baseline QRS durations between the groups (179±14 ms in the pLBBB and 165±20 ms in the dLBBB group, p = 0.1). All patients fulfilled the Strauss criteria with no significant difference in the additional criterion (R wave > 0.1 mV in V1; p = 0.7). In the pLBBB group ED trajectory had an initial leftward direction (six vs. zero patients, p = 0.03) with a uniform (12 vs. one patient, p < 0.001) and slower (0.57 ± 0.12 m/s in the pLBBB vs. 0.75 ± 0.15 m/s in the dLBBB group, p = 0.01) velocity. After 6 months the pLBBB group achieved greater relative QRS duration shortening (26% ± 8% vs. 14% ± 9%; p < 0.02) and relative reductions in end left ventricle systolic volumes (41.3% ± 17.6% vs. 15.8% ± 6.1%; p = 0.004) with better improvement in ejection fraction (17.1% ± 11.0% vs. 5.5% ± 1.0%; p = 0.02). The ED trajectories from 12-lead hrECGs could better differentiate patients with proximal or distal LBBB than standard 12-lead ECG alone.

Fields of Study & Subjects

Cardiac pacing and defibrillation studies Cardiac electrophysiology and arrhythmias ECG Monitoring and Analysis

Publication details

Journal / source
Pacing and Clinical Electrophysiology
Volume
49
Issue
7
Pages
1000–1004
Publication date
21 March 2026
Language