Pulsed Field Ablation of Macro‐Reentrant Atrial Tachycardia Involving the Persistent Left Superior Vena Cava
Abstract
A 51-year-old man with a persistent left superior vena cava (PLSVC) underwent catheter ablation using the PulseSelect PFA Loop catheter (Medtronic). During the procedure, sustained atrial tachycardia (AT) was observed and identified as a macro-reentrant circuit involving the PLSVC. Pulsed field ablation (PFA) applied within the PLSVC successfully terminated the AT without complications. This is a case of macro-reentrant AT involving the PLSVC-left atrium epicardial connection, in which both intracardiac mapping and treatment were performed only using PFA, demonstrating its potential as a safe and effective therapeutic strategy in this challenging anatomical context.
Fields of Study & Subjects
Cardiac Arrhythmias and Treatments
Atrial Fibrillation Management and Outcomes
Cardiac electrophysiology and arrhythmias
Publication details
- Journal / source
- Pacing and Clinical Electrophysiology
- Volume
- 49
- Issue
- 9
- Pages
- 1312–1314
- Publication date
- 13 March 2026
- Language
- EN