Abstract

OBJECTIVE: To report a retrospective study of the outcome of a previously unreported suture pattern for the closure of eyelid margin incisions. ANIMALS STUDIED: Sixty-three canines and six felines. PROCEDURE: The eyelid incisions were closed with a double-layer continuous suture, beginning and finishing at the apex of the incision (i.e., furthest from the eyelid margin), thus positioning the knot at the apex of the incision and distant from the eyelid margin, while still ensuring accurate and secure closure. RESULTS: In this series of 102 eyes of 63 dogs and six cats, the double continuous suture successfully recreated a smooth eyelid margin and was found to be a simple, quick and effective method of closure. CONCLUSIONS: The double continuous eyelid suture accurately and securely closed eyelid incisions involving the eyelid margin, while positioning the knot and suture ends distant from the eyelid margin.

Fields of Study & Subjects

Surgical Sutures and Adhesives Veterinary Medicine and Surgery Ocular Disorders and Treatments

Publication details

Journal / source
Veterinary Ophthalmology
Volume
29
Issue
2
Pages
e70112–e70112
Publication date
2 February 2026