Numerical Investigation of Flow and Heat Transfer in Microchannel With Square Rib Modified by Triangular Extensions

View at publisher Summarise with VIRAT
Authors: Deepak Kumar Raj, Vivek Kumar, Dipankar Sanyal, Aparesh Datta
Cited by: 0
References: 37

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Efficient thermal management is crucial in compact electronic systems, where conventional cooling method often fails under high heat-flux conditions. This study numerically investigates the fluid flow and heat-transfer characteristics in a rectangular microchannel featuring a square rib modified with triangular extensions oriented either upward or downward, named as forward triangular rib connected with square rib (FTRS) and backward triangular rib connected with square rib (BTRS). Three-dimensional numerical investigations have been carried out for Reynolds numbers ranging from 4 to 800 to analyze the flow separation, recirculation, wall shear stress, pressure coefficient, heat-transfer coefficient, velocity deficit, and cooling uniformity index. The results reveal that the orientation of the rib has a significant effect on wake dynamics and thermal performance. The FTRS have a 17% higher returning velocity in the wake, resulting in a large wake and longer recirculation zones at Re = 300. Shear stress analysis revealed that, for a higher Re = 300, the FTRS yielded 44.61% reduction in the maximum bottom wall shear stress and 14.14% reduction in the maximum side-wall shear stress, reflecting a weaker velocity gradient near walls. The pressure distribution revealed a maximum pressure coefficient at the trailing edge for BTRS and at the leading edge for the FTRS. The BTRS achieved a 38.12% higher local heat-transfer coefficient at Re = 300, confirming its superior heat-transfer performance. For both cases, the cooling uniformity index increases with increasing Re, with the BTRS consistently providing a slightly higher cooling uniformity index. Since the BTRS has consistently outperformed the FTRS. Hence, the BTRS configuration has been further analyzed for Re > 500. In this regime, distinct transitions have been observed, at Re = 550, side-wall vortices have merged with the main wake. At Re = 600 and 700, the recirculation bubble has shortened while spreading laterally, and at Re = 800, the flow has become unsteady with periodic vortex shedding. Overall, the BTRS delivered enhanced wake stability, improved wall temperature, and superior thermal performance, making it a promising configuration for advanced microchannel cooling systems.

Fields of Study & Subjects

Heat Transfer and Optimization Heat Transfer Mechanisms Heat Transfer and Boiling Studies

Publication details

Journal / source
Journal of Thermal Science and Engineering Applications
Volume
18
Issue
8
Pages
081014
Publication date
1 August 2026
Language
EN