Feasibility of automatic registration of multiperspective three-dimensional ultrasound images in gynecological brachytherapy

View at publisher Summarise with VIRAT
Authors: Kate E. Rogers, Tiana Trumpour, Aaron Fenster, Jessica Robin Rodgers
Cited by: 0
References: 9

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Brachytherapy is a cancer treatment frequently used for gynecological cancers, where radioactive sources are often delivered via intracavitary applicators temporarily positioned in the vagina and uterus, sometimes alongside needles for optimal dose distribution. Accurate identification of applicators is essential for effective treatment, but their presence causes acoustic shadowing in ultrasound images, obscuring key anatomical features. Although manual registration of three-dimensional (3D) trans-abdominal (TAUS) and trans-rectal (TRUS) ultrasound images can recover obscured regions, the process is time-consuming and clinically impractical. This proof-of-concept study evaluates the feasibility of automatic TRUS-to-TAUS registration using a model-based Iterative Closest Point registration algorithm (ICPREG). A ground truth registration (GTREG) was established by manually aligning TRUS and TAUS volumes of a gynecological phantom containing an applicator and four needles. To isolate the performance of ICPREG, all identifiable features were used to position an applicator model within the registered volumes. ICPREG established a TRUS-to-TAUS transformation between applicator models. Target Registration Error (TRE) was calculated between the transformed TRUS and TAUS images using localized needle tips. ICPREG achieved a mean surface distance of 1.4 × 10-5 mm between the transformed applicators, demonstrating successful algorithmic alignment of the models. The TRE between the TRUS and TAUS images after ICPREG was 2.08 mm, matching the TRE of the GTREG, indicating that ICPREG produced an equivalent registration. These results demonstrate that ICPREG can accurately produce the TRUS-to-TAUS registration based on applicator models. This approach may support improved intraoperative visualization of applicator placement, offering a more accessible and clinically feasible alternative to current imaging techniques.

Fields of Study & Subjects

Medical Image Segmentation Techniques Advanced Radiotherapy Techniques Anatomy and Medical Technology

Publication details

Journal / source
SPIE Medical Imaging: Image-Guided Procedures, Robotic Interventions, and Modeling
Pages
14–14
Publication date
1 April 2026
Language
EN