Automated breast boundary extraction from reflection data in QTI breast acoustic CT

View at publisher Summarise with VIRAT
Authors: Linh Nguyen, James W. Wiskin, Kevin Tavenner, Bilal H. Malik
Cited by: 0
References: 4

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The QTI Breast Acoustic CT scanner, an ultrasound-based tomographic imaging system, produces two complementary datasets: transmission and reflection, that are processed through distinct algorithms to reconstruct high-resolution 3D images of the breast. Accurate detection of the breast support region, the anatomical boundary separating breast tissue from surrounding water, is a critical step in this pipeline, as it influences multiple aspects of the imaging process. The breast support serves as the initial guess for the nonlinear optimization algorithm that reconstructs speed-of-sound (SOS) and attenuation images from transmission data, a process that is highly sensitive to initialization because of the presence of numerous local minima. Additionally, the breast support determines the correct signal gain factor during reflection image reconstruction, as well as enables post-processing by denoising the water region in the final images and provides the geometric basis for calculation of total breast volume used to assess breast tissue composition. To extract the breast support, we developed a robust multi-step algorithm that leverages the reflection dataset. The process begins by detecting primary reflection events in each single-view time series, identifying the earliest strong reflections corresponding to the skin surface. These events are refined through filtering to remove unreliable signals and interpolation to stabilize the detections. Missing data near the chest wall are compensated through extrapolation. The refined events are then backprojected into 3D space, forming an initial point cloud representing the breast surface. This point cloud is denoised, and for each coronal slice, angular binning is applied to compute robust median boundary points. These points are smoothed using trigonometric polynomial fitting, and the resulting continuous surface undergoes additional postprocessing to ensure anatomical consistency.

Fields of Study & Subjects

Microwave Imaging and Scattering Analysis Ultrasound Imaging and Elastography Photoacoustic and Ultrasonic Imaging

Publication details

Journal / source
SPIE Medical Imaging: Ultrasonic Imaging and Tomography
Pages
18–18
Publication date
2 April 2026