Repeated evaluation of synovial inflammation in CMC-1 osteoarthritis patients via 3D ultrasound

View at publisher Summarise with VIRAT
Authors: Clara Duquette-Evans, Megan Hutter, Randa Mudathir, Carla du Toit, Aaron Fenster, Emily Lalone
Cited by: 0
References: 4

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Synovial inflammation, or synovitis, is a well-known feature of osteoarthritis (OA).While X-ray radiography is still the most commonly used imaging modality to evaluate OA, it is unable to detect soft tissue changes, such as synovitis or abnormal angiogenesis. However, synovitis has been shown to correlate with patient-reported pain and has been highlighted as a potential driver of cartilage degradation. Characterizing the inflammatory profile and subsequent changes in disease outcomes in OA-affected joints is therefore an important strategy to strengthen our understanding of disease pathogenesis and progression. The goals of this study were to provide (1) a quantitative evaluation of synovial inflammation based on repeated measures, and (2) potential use of 3D ultrasound-based phenotypes of OA in the CMC-1 joint. To quantitate synovial tissue volume, our lab has developed a 3D ultrasound imaging system, composed of a linear motorized scanner and water bath. This system allows the capture of 3D ultrasound images of the CMC-1 joint and subsequent segmentation of the synovial tissue volume (STV). 36 CMC-1 OA patients underwent 3D ultrasound imaging 2-3 times over a 1-year period. STV values as well as pinch grip force and patient-reported pain measures were collected each time. Segmentation of the STV was performed using 3D Slicer software by one observer. The intra-reliability for the segmentations was calculated, as was the Minimal Detectable Change (MDC) in STV. Our results showed that there is great variability in STV, both between patients and within many patients as well. The intra-reliability for STV segmentations was very high, with an interclass correlation coefficient of 0.98 while the MDC was determined to be 13.80 mm3. Our results indicate that while synovial inflammation presents differently across patients, the 3D ultrasound imaging system provides a sensitive and precise method for monitoring STV in the CMC- 1 joint.

Fields of Study & Subjects

Osteoarthritis Treatment and Mechanisms Rheumatoid Arthritis Research and Therapies Hip disorders and treatments

Publication details

Journal / source
SPIE Medical Imaging: Ultrasonic Imaging and Tomography
Pages
43–43
Publication date
2 April 2026
Language
EN