Adding organ texture to boundary representation computational phantoms using analytical solid noise synthesis

View at publisher Summarise with VIRAT
Authors: Andreu Badal
Cited by: 0
References: 19

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Computational models of medical imaging devices and sophisticated anatomical phantoms are commonly used to generate realistic x-ray projections for device optimization and objective image quality evaluation. An insufficiently studied limitation of simulated images is that organs in computational phantoms are typically uniform, and the simulated projections do not display the fine tissue textures seen in clinical images. Random tissue textures are an additional source of variability that can reduce lesion detectability, but also provide clinically relevant diagnostic information. Previous efforts to include intra-organ texture have focused on voxelized phantoms with stochastic variations in voxel composition, but to our knowledge, no general method exists to add texture inside phantoms described by boundary representation geometric models such as triangle meshes or Non-Uniform Rational B-Spline (NURBS) surfaces. We introduce a methodology to extend the NURBS projector in the opensource XCIST x-ray simulation toolkit to incorporate stochastic 3D textures inside computational phantoms at arbitrary resolution, without requiring voxelization. The foundation of the algorithm is to add a zero-mean solid noise field to the nominal attenuation coefficient of each tissue type, and analytically integrate the random field during the ray-tracing process. We synthesize the analytical solid noise, which we call waveNoise, by superposing thousands of 3D plane waves (i.e., cosine functions) with randomized parameters (direction, frequency, amplitude and phase). This process generates an interference pattern that converges to an approximately Gaussian random noise field by virtue of the Central Limit Theorem. By controlling how wave frequencies are sampled, the spatial correlations in the resulting texture can be tuned (e.g., band-limited or approximating a power-law spectrum). During the process of simulating an x-ray projection of a NURBS phantom, line integrals across the organs with waveNoise can be calculated by evaluating only two sine functions for each cosine wave in the noise, which is a moderately fast calculation in modern CPUs. The model properties were studied using ideal CT simulations of a uniform object, showing convergence to a Gaussian noise field and the ability to approximate desired power-law textures. The model was also tested in a sophisticated simulation of an abdominal CT and a chest radiograph of the NURBS-based XCAT phantom distributed with XCIST. The results demonstrate successful incorporation of a complex texture inside the liver, and a more natural appearance of the lung and bone regions. This analytical approach can incorporate additional integrable attenuation variations (e.g., Gaussian signals for lesions), enabling task-based evaluation studies with known ground truth at arbitrary resolution. Future work will combine radiomics-informed and biologically based spectrum matching with runtime acceleration to enable organ-specific textures for high-fidelity virtual imaging trials, full-reference image quality evaluation, and radiomics validation studies.

Fields of Study & Subjects

Advanced X-ray and CT Imaging Radiation Dose and Imaging Advanced Radiotherapy Techniques

Publication details

Journal / source
SPIE Medical Imaging: Physics of Medical Imaging
Pages
37–37
Publication date
2 April 2026
Language
EN