Evaluation of fluence reduction versus sparsity for diffusion posterior sampling reconstruction in low-dose CT

Read full text Summarise with VIRAT
Authors: Zimo Liu, Xin Eric Wang, Xiao Jiang, Altea Lorenzon, Grace J. Gang, Joseph Webster Stayman
Cited by: 0
References: 10

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Low-dose computed tomography (CT) remains a popular research topic with the advent of an increasing number of algorithmic solutions to control noise. One such approach that enforces data consistency through a model-based data likelihood term but that also includes a deep learning generative prior is Diffusion Posterior Sampling (DPS). This technique is formulated within a probabilistic framework and is capable of generating high-quality reconstructions under noisy and/or undersampled conditions. However, one major unanswered question is, given the opportunity to design a low-dose protocol, how should low dose be achieved - through sparse sampling or reduced fluence per projection. In this work, we conducted a simulation study and systematically investigated the impact of acquisition parameters - the number of views ( n view ) and incident photons per view ( I 0 ) - on DPS-based CT reconstruction. We performed a 2D sweep over different combinations of the number of views ( n view ) and incident photons per view ( I 0 ) and compared reconstructions with an equivalent total incident photons (TIP). Reconstruction quality was evaluated in terms of PSNR (Peak Signal-to-Noise Ratio), bias, and posterior sample variability. We found that the number of views had a strong influence on image quality and that most performance curves showed a transition where too few views had a large negative impact on performance. We observed that there is an advantage to be gained by jointly optimizing both the fluence per view and the number of views, with a trend of an increasing number of views required for a higher total incident fluence. These findings provide a strategy for optimizing CT acquisition protocols that adapt both fluence per view and sparsity to optimally maintain image quality at reduced radiation doses.

Fields of Study & Subjects

Radiation Dose and Imaging Medical Imaging Techniques and Applications Advanced X-ray and CT Imaging

Publication details

Journal / source
SPIE Medical Imaging: Physics of Medical Imaging
Volume
13924
Pages
52–52
Publication date
2 April 2026
Language
EN