A contactless gaze-to-reaction-time pipeline for screening-oriented visual field assessment

View at publisher Summarise with VIRAT
Authors: Samarla Puneeth, Anjani Bollapragada, Paul Chong, Eungjoo Lee
Cited by: 0
References: 19

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Standard automated perimetry is the clinical gold standard for visual field assessment. However, it requires stable fixation, manual button responses, and supervised clinic workflows, limiting scalability for screening and for patients with motor or attention constraints. Gaze-driven perimetry can remove handheld response devices by inferring stimulus detection and reaction time from eye movements, but robust gaze estimation and event-level reaction time extraction remain challenging under real-world noise, such as blinks, head motion, and variable capture conditions. To address these challenges, we present a webcam-only gaze-to-reaction-time perimetry pipeline that (1) delivers Humphrey Visual Field (HVF)-format stimuli, (2) predicts per-frame gaze direction using lightweight vision models against stimulus-derived pseudo–ground-truth labels (assuming compliant gaze-following behavior), and (3) aligns gaze trajectories to known stimulus onsets. We then apply reliability-aware confirmation to stabilize event-level reaction time estimates. In this study, we evaluate three gaze estimators— Ridge HOG/PCA, MobileNetV2, and a DeiT-style transformer—under Leave-One-Subject-Out cross-validation on nine adult volunteers. MobileNetV2 achieves 4.35° ± 1.13° yaw MAE and 4.96° ± 1.33° pitch MAE, with 7.43° ± 0.39° 2D angular error, compared to 26.00° ± 25.96° for the non-deep baseline. DeiT-Tiny attains comparable performance (4.33° ± 1.12° yaw MAE; 7.62° ± 0.41° 2D error). In practical terms, 7–8° gaze-direction error corresponds to a coarse but usable directional estimate, on the order of several centimeters of point-of-regard uncertainty at typical laptop viewing distances, which is sufficient to distinguish central fixation from peripheral target shifts in our HVF-format grid. For reaction time estimation, stimulus-aligned detection reduces variance relative to naive peak-based logic, and reliability-aware confirmation further improves RT stability while maintaining a low miss rate. These results support the feasibility of contactless, webcam-based gaze-to-reaction-time perimetry for screening-oriented visual field assessment, motivating larger studies to quantify clinical sensitivity relative to standard automated perimetry.

Fields of Study & Subjects

Gaze Tracking and Assistive Technology Glaucoma and retinal disorders Retinal Imaging and Analysis

Publication details

Journal / source
SPIE Medical Imaging: Image Perception, Observer Performance, and Technology Assessment
Pages
39–39
Publication date
2 April 2026
Language