DBTMI database characterization and artifacts reduction: the first 100 clinical datasets

View at publisher Summarise with VIRAT
Authors: Predrag R. Bakić, Magnus Dustler, Sophia Zackrisson, Anders Tingberg
Cited by: 0
References: 7

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Simultaneous digital breast tomosynthesis (DBT) and mechanical imaging (MI) – DBTMI – is a novel, multimodality approach to early breast cancer screening, combining high sensitivity of DBT imaging, and improved specificity of tissue stiffness analysis by MI. We have been collecting clinical DBTMI, with ethics approval, in an observational study at the Skane University Hospital Malmö. To date, we collected DBTMI data from over 250 women. Here we present the first 100 datasets organized in a database. The DBTMI datasets in the database were collected in the period May 2021 – September 2022, using a DBTMI prototype consisting of a clinical DBT system and a commercially available pressure sensor positioned on the breast support of the DBT machine. We have recruited women recalled from screening. Upon informed consent, each woman received a DBTMI exam of one breast. In addition, for each woman, we acquired a DBT of a uniform Lucite block on top of the sensor, used in postprocessing based upon flat-fielding to reduce sensor artifacts seen in x-ray images. The participating women had the mean age of 57.3 years (40-75; median 56). We reviewed the visibility of sensor artifacts in the central DBT projection after postprocessing. No artifacts were noted in 48% of images, 34% had minimal, and 18% visible artifacts. For seven women, the Lucite images did not include the sensor, which caused clearly seen artifacts. Their DBTMI images were postprocessed in a hybrid approach, using Lucite images from other women shifted to match the sensor position. In a semi-automated matching, we identified sensor element crossings. The distance between the element crossings in DBTMI and Lucite images were estimated, and used to shift Lucite images before flat-fielding. Remaining artifacts after hybrid flat-fielding have been assessed visually. Almost all processed images (6/7) showed no or minimal artifacts; only one had slightly visible remaining artifacts. Quantification of artifacts is ongoing, using, e.g., Fast Fourier Transform. Future work includes observer studies with clinical radiologists, and the analysis of clinical accuracy comparing DM, DBT, and DBTMI screening.

Fields of Study & Subjects

Digital Radiography and Breast Imaging Ultrasound Imaging and Elastography AI in cancer detection

Publication details

Journal / source
SPIE Medical Imaging: Physics of Medical Imaging
Pages
47–47
Publication date
2 April 2026
Language
EN