Investigation on the corrosion causes of 3Cr tubing in a gas-lift well

View at publisher
Authors: Nan Ji, Chao Zhang, Hongwei Li, Yan Long, Peng Wang
Cited by: 0

Abstract

The corrosion causes of 3Cr tubing were analyzed by physical and chemical performance tests, metallographic examination of the tubing material, scanning electron microscope (SEM), energy dispersive spectrometer (EDS) and Xray diffraction (XRD) analysis of the corrosion morphology and corrosive products, in order to figure out the main causes of the corrosion and draw up useful suggestions for the preventive measures. The results indicated that the mechanical properties and the chemical composition of the coupling and tubing material all meet the corresponding standard requirements. The form of the corrosion was oxygen corrosion, the main causes for the corrosion was the gas lift operation in the a-annulus, in which the injected nitrogen gas contain a certain amount of oxygen, and resulted in the occurrence of the dissolved oxygen corrosion on the outer surface of the tubing.

Fields of Study & Subjects

Corrosion Behavior and Inhibition Hydrogen embrittlement and corrosion behaviors in metals Material Properties and Failure Mechanisms

Publication details

Journal / source
International Conference on Mechanical Engineering and Materials (ICMEM)
Pages
136–136
Publication date
15 February 2026
Language
EN