A wearable quantum magnetometer for high-fidelity, motion-resistant heart rate variability monitoring
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
Heart Rate Variability (HRV)) is one of the most relevant, non-invasive, biomarkers for the assessment of ANS function. Nevertheless, however, its transfer to ambulatory monitoring scenarios is limited, essentially due to the high susceptibility of the wearable sensors, particularly photoplethysmography (PPG), to motion artefacts. Contemporary cardiovascular surveillance is based mainly on electrocardiography (ECG) and PPG, for which a large degree of degradation occurs in realistic environmental noise problems. Emerging methods of quantum-origin and specifically room temperature diamond-based magnetocardiography (MCG) offer potentially better alternatives; however, insufficient computational frameworks that compare the performance of these methods versus traditional modalities in noisy environments are present in the literature. This study presents an approach for a theoretical and computational framework for the development of a wearable MCG system, based on nitrogen-vacancy NV centres in the diamond crystal. Based on the expectation of achieving high sensitivity alternating current (ac) magnetometry, the current study develops a foundation for ac magnetometry in the form of a derived governing spin Hamiltonian model and the modeling of optically detected magnetic resonance. Lock-in Amplifier Employing Lock-in Amplification, the sensitivity figures have been projected and reached the order of picotesla/sqrt Hz, which is sufficient to detect cardiac magnetic fields. To consider the practical feasibility, we created a computational model in which NV-GMC is compared to PPG. An artificial electrocardiogram signal was mathematically converted into corresponding biomagnetic and blood volume pulse signals. Distinct noise models were superimposed, namely additive Gaussian noise and low frequency (50 Hz) interference for the MCG signals and mainly low frequency sinusoidal motion artefacts for the PPG signals. Simulation results showed that a standard peak detection algorithm is able to reliably extract beat-to-beat intervals from the noisy MCG data, whereas PPG analysis is not able to do so - leading to artefacts of more than 30% and implausible metrics in HRV analysis. These results show that NV- diamond based MCG is inherently resistant to motion artefacts and present a good validation for the further development of this next generation technology for the delivery of medical grade, wearable cardiovascular monitoring.
Fields of Study & Subjects
Non-Invasive Vital Sign Monitoring
Diamond and Carbon-based Materials Research
Heart Rate Variability and Autonomic Control
Publication details
- Journal / source
- International Conference on Optical and Wireless Technologies (OWT)
- Pages
- 128–128
- Publication date
- 30 March 2026
- Language
- EN