The CEPC Clock Issue and Fine-tuning of the Circumference

Read full text
Authors: Dou Wang, Jie Gao, J.H. Wang, Dapeng Jin, Xiaohao Cui, Ge Lei, Cai Meng, Wei Wei, J M Ye, Yiwei Wang, Jiyuan Zhai, Yanping Li
+4 more Zhi Ma, Jun Hu, Shengsen Sun, X J Wang
Cited by: 0

Abstract

The CEPC clock issue is related with the RF frequency coordination between the various accelerator systems and may affect the operation modes of both the accelerator and the detector. The timing structure of CEPC has been restudied with the collaboration of the accelerator team and the detector team. After discussions between two sides, the CEPC bunch structure is set such that the spacings between adjacent bunches in any CEPC operation mode are integer numbers of 23.08 ns. The master CEPC clock will be provided by the accelerator to the detector systems with a frequency of 43.33 MHz, synchronous to the beam. The CEPC detector system relies on the clock to sample physics signal at the right time. It was found that if the circumference of CEPC is slightly changed to 99955.42 m, the detector would benefit more for the first 10-year operation.

Fields of Study & Subjects

Particle Accelerators and Free-Electron Lasers Advanced Frequency and Time Standards Particle Detector Development and Performance

Publication details

Journal / source
International Journal of Modern Physics A
Publication date
11 September 2026
Language
EN