Sub-nanometer thermal and spectral stability of fiber Bragg gratings in dual-mode optomechanical sensors
Abstract
Precise wavelength stability and narrow spectral linewidths are essential for enhancing the performance of optical sensors in biomedical diagnostics and environmental gas detection. This work presents a detailed investigation of fiber Bragg gratings (FBGs) integrated within a dual-mode laser sensor system based on intra-cavity absorption spectroscopy. The Bragg wavelength stability was characterized over extended periods, demonstrating fluctuations of up to ±0.3[Formula: see text]nm without thermal insulation, which were significantly reduced to ±0.1[Formula: see text]nm with the implementation of styrofoam enclosures. Furthermore, the laser’s full width at half maximum (FWHM) was analyzed under varying injection currents, attaining a minimum linewidth of 0.06[Formula: see text]nm, thereby improving spectral selectivity. To the best of our knowledge, this is the first systematic investigation of long-term Bragg wavelength stability and FWHM behavior in a dual-mode intra-cavity absorption spectroscopy configuration, providing quantitative stability limits directly relevant to the design of highly selective gas sensors.
Fields of Study & Subjects
Advanced Fiber Optic Sensors
Mechanical and Optical Resonators
Spectroscopy and Laser Applications
Publication details
- Journal / source
- Journal of Nonlinear Optical Physics & Materials
- Publisher
- World Scientific Pub Co Pte Ltd
- Publication date
- 18 July 2026
- Language
- EN