Real‐World Experience With Control‐IQ Technology in Saudi Children With Insulin‐Dependent Diabetes: A Single‐Center Observational Study
Abstract
Objectives The Tandem t:slim X2 insulin pump with the Control‐IQ technology (Control‐IQ) is an automated insulin delivery (AID) system for glycemic control but has limited data in Saudi pediatric and young adult populations. We aim to evaluate the efficacy and safety of Control‐IQ therapy in children with insulin‐dependent diabetes and previously treated with multiple daily injections (MDIs). The primary outcome is to assess the change in HbA1c 6 months after initiating Control‐IQ technology. Methods This prospective observational study evaluated children aged 2–14 years with insulin‐dependent diabetes who transitioned from treatment with MDI to the Control‐IQ technology in the diabetes clinic at the King Faisal Specialist Hospital and Research Centre (KFSHRC) in Saudi Arabia. Results A total of 100 patients (44 boys and 56 girls; median age was 11 years) were included. Most (82%) had a history of severe hypoglycemia. Following Control‐IQ initiation, median HbA1c significantly decreased from 9.2% to 6.9% at 6 months (−25.0%; p < 0.001), accompanied by a 24.4% reduction in the daily insulin dose. Time in range (TIR) (70–180 mg/dL) improved from 45.6% to 68.8% (+23.2%; p < 0.001), while time in significant hypoglycemia (
Fields of Study & Subjects
Diabetes Management and Research
Diabetes and associated disorders
Diabetes Management and Education
Publication details
- Journal / source
- Pediatric Diabetes
- Volume
- 2026
- Issue
- 1
- Pages
- 6113065–6113065
- Publication date
- 1 January 2026
- Language
- EN