Balloon- Versus Self-Expanding Transcatheter Valves for Failed Small Surgical Aortic Bioprostheses: 3-Year Results of the LYTEN Trial
Abstract
BACKGROUND: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (TAVR) field have been obtained from retrospective studies. This prespecified secondary analysis of the LYTEN randomized trial (Comparison of the Balloon-Expandable Edwards Valve and Self-Expandable CoreValve Evolut R or Evolut PRO System for the Treatment of Small, Severely Dysfunctional Surgical Aortic Bioprostheses) aims to compare the 3-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in valve-in-valve TAVR. METHODS: Patients with a failed small (≤23 mm) surgical valve undergoing valve-in-valve TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 3-year follow-up. Study outcomes were defined according to VARC (Valve Academic Research Consortium)-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient
Fields of Study & Subjects
Cardiac Valve Diseases and Treatments
Aortic Disease and Treatment Approaches
Congenital Heart Disease Studies
Publication details
- Journal / source
- Circulation Cardiovascular Interventions
- Publisher
- Ovid Technologies (Wolters Kluwer Health)
- Volume
- 19
- Issue
- 3
- Pages
- e016255–e016255
- Publication date
- 2 February 2026
- Language
- EN