Prospective Midterm Outcomes of the PULSTA Self-Expandable Transcatheter Pulmonary Valve: The PULSTA CE Approval Study
Abstract
BACKGROUND: Patients with congenital or acquired right ventricular outflow tract dysfunction frequently require pulmonary valve replacement and are exposed to repeated surgical interventions due to prosthetic valve degeneration. The PULSTA self-expanding transcatheter pulmonary valve was designed to address a broad spectrum of native and surgically repaired right ventricular outflow tract anatomies. This study reports the midterm safety, hemodynamic performance, and durability outcomes of the prospective, multinational PULSTA CE approval trial (PULSTA Carpentier Edwards). METHODS: This premarket, multicenter, nonrandomized study enrolled 58 patients across 11 centers in 6 countries. Successful PULSTA implantation was achieved in 57 patients (98.3%), including 4 valve-in-valve procedures. Patients were followed for a median duration of 4.1 years. Primary end points included procedural or device-related serious adverse events, hemodynamic improvement, and sustained valve function. RESULTS:
Fields of Study & Subjects
Congenital Heart Disease Studies
Cardiac Valve Diseases and Treatments
Shoulder Injury and Treatment
Publication details
- Journal / source
- Circulation Cardiovascular Interventions
- Publisher
- Ovid Technologies (Wolters Kluwer Health)
- Volume
- 19
- Issue
- 9
- Pages
- e016616–e016616
- Publication date
- 18 June 2026
- Language
- EN