Abstract WP247: Enhanced Detection of Acute Ischemic Stroke with Low-Field MRI

View at publisher
Authors: Annabel Sorby‐Adams, Nandor K. Pinter, Amelia Demopoulos, JOHN E. KIRSCH, Vinay Jaikumar, Olivia Nelson, Stephen Bacchi, Jennifer D. Guo, Blair Alden Parry, Hailey Brigger, Ian Johnson, Adam de Havenon
+11 more Gordon K. Sze, Vivien Lee, Keith W. Muir, Shahid Mehdi Nimjee, Adnan Hussain Siddiqui, Kathryn E. Keenan, Matthew Scott Rosen, Juan Eugenio Iglesias, Kevin Navin Sheth, Joshua Goldstein, William Taylor Kimberly
Cited by: 0

Abstract

Introduction: Portable, low-field (LF) magnetic resonance imaging (MRI) has the potential to expand access to neuroimaging in environments where conventional MRI is limited. However, diffusion-weighted imaging (DWI) at LF is challenged by a low signal-to-noise ratio and gradient strength, which may limit diagnostic confidence in acute ischemic stroke (AIS) evaluation, particularly for very small strokes. To address this gap, we evaluated a combination of novel LF-MRI hardware and pulse sequences to enhance lesion detection. Methods: Patients with a suspected diagnosis of AIS were prospectively enrolled at three US centers and underwent single-direction DWI and apparent diffusion coefficient (ADC) imaging on a 0.064 T MRI (v1, Hyperfine Inc.). A multi-direction DWI sequence (comprising 3 orthogonal diffusion direcions) was developed for comparison. Additionally, a next-generation 0.064 T scanner with optimized gradient amplifiers, form factor, and cooling system was evaluated (v2, Hyperfine Inc.). Diagnostic accuracy and the lower limit of lesion detection was calculated for both single-direction and multi-direction images compared to ground-truth MRI (1.5-3 T). Results: A total of 95 patients ( n =62 confirmed ischemic stroke; n =33 stroke mimics) were included. On single-direction images, agreement between assessors regarding lesion detection was κ=0.72, and κ=0.84 on multi-direction images. The positive predictive value for differentiating AIS from stroke mimics was 78.2% on single-direction images and 95% for multi-direction trace maps. On single-direction images, a lesion volume cut-point of 0.6 mL yielded a sensitivity of 89% and specificity of 88%. For multi-direction trace maps, the lesion volume cut-point was 0.4 mL, with a corresponding sensitivity of 86% and specificity of 83%. Multi-direction imaging on the next generation v2 hardware improved image uniformity (p

Fields of Study & Subjects

Advanced MRI Techniques and Applications Acute Ischemic Stroke Management Advanced Neuroimaging Techniques and Applications

Publication details

Journal / source
Stroke
Volume
57
Issue
Suppl_1
Publication date
29 January 2026
Language